OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344825708 0213600 2020-07-07 479 CENTER STREET, LEWISTON, NY, 14092
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2020-07-07
Case Closed 2023-04-25

Related Activity

Type Inspection
Activity Nr 1482551
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2020-08-14
Current Penalty 1735.0
Initial Penalty 1735.0
Final Order 2020-09-11
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 7/7/2020 at a roof project located at 479 Center Street, Lewiston, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2020-08-14
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-09-11
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 7/7/2020 at a roof project located at 479 Center Street, Lewiston, New York; employees were placing shingles on the roof of a two story building. The roof had a 6 in 12 pitch with an eave height of approximately 22 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED