Name: | LEGACY CONSTRUCTION SERVICES, LLC |
Jurisdiction: | New York |
Legal type: | FOREIGN LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 21 Mar 2019 (6 years ago) |
Entity Number: | 5518298 |
ZIP code: | 12260 |
County: | Erie |
Place of Formation: | Ohio |
Address: | 99 WASHINGTON AVENUE, SUITE 700, ALBANY, NY, United States, 12260 |
Name | Role | Address |
---|---|---|
C/O REGISTERED AGENT SOLUTIONS, INC. | DOS Process Agent | 99 WASHINGTON AVENUE, SUITE 700, ALBANY, NY, United States, 12260 |
Name | Role | Address |
---|---|---|
REGISTERED AGENT SOLUTIONS, INC. | Agent | 99 WASHINGTON AVENUE, SUITE 700, ALBANY, NY, 12260 |
Start date | End date | Type | Value |
---|---|---|---|
2024-11-13 | 2025-03-06 | Address | 99 WASHINGTON AVENUE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Service of Process) |
2024-11-13 | 2025-03-06 | Address | 99 WASHINGTON AVENUE, SUITE 700, ALBANY, NY, 12260, USA (Type of address: Registered Agent) |
2023-03-01 | 2024-11-13 | Address | 99 WASHINGTON AVENUE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Registered Agent) |
2023-03-01 | 2024-11-13 | Address | 99 WASHINGTON AVENUE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Service of Process) |
2021-08-05 | 2023-03-01 | Address | 99 WASHINGTON AVENUE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Service of Process) |
2021-08-05 | 2023-03-01 | Address | 99 WASHINGTON AVENUE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Registered Agent) |
2021-04-27 | 2021-08-05 | Address | 99 WASHINGTON AVENUE, SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Service of Process) |
2019-11-27 | 2021-04-27 | Address | 122 EAST 42ND STREET, 18TH FLOOR, NEW YORK, NY, 10168, USA (Type of address: Service of Process) |
2019-03-21 | 2019-11-27 | Address | 10 EAST 40TH STREET, 10TH FLOOR, NEW YORK, NY, 10016, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
250306002483 | 2025-03-06 | BIENNIAL STATEMENT | 2025-03-06 |
241113000048 | 2024-10-28 | CERTIFICATE OF CHANGE BY AGENT | 2024-10-28 |
230301005044 | 2023-03-01 | BIENNIAL STATEMENT | 2023-03-01 |
210805001360 | 2021-08-04 | CERTIFICATE OF CHANGE BY ENTITY | 2021-08-04 |
210427060249 | 2021-04-27 | BIENNIAL STATEMENT | 2021-03-01 |
SR-113479 | 2019-11-27 | CERTIFICATE OF CHANGE | 2019-11-27 |
190513000558 | 2019-05-13 | CERTIFICATE OF PUBLICATION | 2019-05-13 |
190321000447 | 2019-03-21 | APPLICATION OF AUTHORITY | 2019-03-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346161755 | 0213600 | 2022-08-19 | 925 ROBIN ROAD, AMHERST, NY, 14228 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B10 |
Issuance Date | 2022-09-26 |
Current Penalty | 3698.0 |
Initial Penalty | 3698.0 |
Final Order | 2022-10-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 8/18/2022, at the roof area of the site, Amherst, NY. Employee of Five Star Roofing, working on roofing paper and plywood boards, was not protected by fall protections. Employee was exposed to fall of 8 feet and 14 feet due to the slanted roof. Controlling Employer, Legacy Construction Services LLC, did not enforce the use of fall protections. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2022-09-26 |
Current Penalty | 0.0 |
Initial Penalty | 3698.0 |
Final Order | 2022-10-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13):The top or top step of a stepladder was used as a step: a) On or about 8/18/2022, at the ground area of the site, Amherst, NY. Employee of Five Star Roofing, while discussing with the owner about roofing transition details, had one foot on the top step and the other foot on the top of a 6-foot Warner step ladder. Employee was exposed to fall of 6 feet. Controlling Employer, Legacy Construction Services LLC, did not enforce the proper use of ladders. NO ABATEMENT CERTIFICATION REQUIRED |
Date of last update: 23 Mar 2025
Sources: New York Secretary of State