Name: | PC CONSTRUCTION SYSTEMS, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 10 Apr 2019 (6 years ago) |
Entity Number: | 5531583 |
ZIP code: | 14221 |
County: | Erie |
Place of Formation: | New York |
Address: | 1967 WEHRLE DRIVE, SUITE 1-055, WILLIAMSVILLE, NY, United States, 14221 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Unique Entity ID | Expiration Date | Physical Address | Mailing Address | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EQH6MM9NY7B5 | 2024-05-08 | 1967 WEHRLE DR STE 1055, BUFFALO, NY, 14221, 8452, USA | 1967 WEHRLE DRIVE SUITE #1-055, SUITE #1-055, WILLIAMSVILLE, NY, 14221, 8452, USA | |||||||||||||||||||||||||||||||||||||||||||||
|
Doing Business As | PC CONSTRUCTION SYSTEMS |
Division Name | PC CONSTRUCTION SYSTEMS, INC. |
Congressional District | 26 |
State/Country of Incorporation | NY, USA |
Activation Date | 2023-05-30 |
Initial Registration Date | 2023-04-18 |
Entity Start Date | 2019-04-17 |
Fiscal Year End Close Date | Dec 31 |
Service Classifications
NAICS Codes | 238910 |
Points of Contacts
Electronic Business | |
---|---|
Title | PRIMARY POC |
Name | WILLIAM L PUTMAN |
Role | CHIEF OPERATING OFFICER |
Address | 1967 WEHRLE DRIVE SUITE 1 055, WILLIAMSVILLE, NY, 14221, 8452, USA |
Government Business | |
---|---|
Title | PRIMARY POC |
Name | WILLIAM L PUTMAN |
Role | EXECUTIVE VICE PRESIDENT |
Address | 1967 WEHRLE DRIVE SUITE 1 055, WILLIAMSVILLE, NY, 14221, 8452, USA |
Past Performance | Information not Available |
---|
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 1967 WEHRLE DRIVE, SUITE 1-055, WILLIAMSVILLE, NY, United States, 14221 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
190917000511 | 2019-09-17 | CERTIFICATE OF AMENDMENT | 2019-09-17 |
190410000422 | 2019-04-10 | CERTIFICATE OF INCORPORATION | 2019-04-10 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343909958 | 0213600 | 2019-04-04 | 948 KENSINGTON AVENUE, BUFFALO, NY, 14215 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2019-04-09 |
Current Penalty | 1400.0 |
Initial Penalty | 2273.0 |
Final Order | 2019-05-03 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 4/4/19 at a roof project located at 948 Kensington Avenue, Buffalo, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 I |
Issuance Date | 2019-04-09 |
Current Penalty | 2325.0 |
Initial Penalty | 3789.0 |
Final Order | 2019-05-03 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 4/4/19 at a roof project located at 948 Kensington Avenue, Buffalo, New York; employees performing roofing activities from a ladder jack scaffold approximately 18 feet high were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2019-04-09 |
Current Penalty | 2325.0 |
Initial Penalty | 3789.0 |
Final Order | 2019-05-03 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 4/4/19 at a roof project located at 948 Kensington Avenue, Buffalo, New York; employees were placing sheathing on the roof of a two story house. The roof had an 8 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
Status | User ID | Name of Firm | Trade Name | UEI | Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Active | P3140762 | PC CONSTRUCTION SYSTEMS, INC. | PC CONSTRUCTION SYSTEMS | EQH6MM9NY7B5 | 1967 WEHRLE DR STE 1055, BUFFALO, NY, 14221-8452 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
HUBZone Certified | No |
Women Owned Certified | No |
Women Owned Pending | No |
Economically Disadvantaged Women Owned Certified | No |
Economically Disadvantaged Women Owned Pending | No |
Veteran-Owned Small Business Certified | No |
Veteran-Owned Small Business Joint Venture | No |
Service-Disabled Veteran-Owned Small Business Certified | No |
Service-Disabled Veteran-Owned Small Business Joint Venture | No |
Bonding Levels
Description | Construction Bonding Level (per contract) |
Level | (none given) |
Description | Construction Bonding Level (aggregate) |
Level | (none given) |
Description | Service Bonding Level (per contract) |
Level | (none given) |
Description | Service Bonding Level (aggregate) |
Level | (none given) |
NAICS Codes with Size Determinations by NAICS
Primary | Yes |
Code | 238910 |
NAICS Code's Description | Site Preparation Contractors |
Buy Green | Yes |
Code | 236220 |
NAICS Code's Description | Commercial and Institutional Building Construction |
Buy Green | Yes |
Export Profile (Trade Mission Online)
Exporter | Firm hasn't answered this question yet |
Export Business Activities | (none given) |
Exporting to | (none given) |
Desired Export Business Relationships | (none given) |
Description of Export Objective(s) | (none given) |
Date of last update: 23 Mar 2025
Sources: New York Secretary of State