Search icon

LEATHERSTOCKING PROFESSIONAL SERVICES, LLC

Company Details

Name: LEATHERSTOCKING PROFESSIONAL SERVICES, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 24 Apr 2019 (6 years ago)
Entity Number: 5540020
ZIP code: 13340
County: Herkimer
Place of Formation: New York
Address: 2646 WELSHBUSH ROAD, FRANKFORT, NY, United States, 13340

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
7UUW8 Obsolete Non-Manufacturer 2017-04-25 2024-09-11 2024-09-10 No data

Contact Information

POC EMIL H.. STREETER
Phone +1 315-525-1326
Address 2646 WELSHBUSH RD, FRANKFORT, HERKIMER, NY, 13340 4721, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

DOS Process Agent

Name Role Address
EMIL H. STREETER DOS Process Agent 2646 WELSHBUSH ROAD, FRANKFORT, NY, United States, 13340

Filings

Filing Number Date Filed Type Effective Date
190708000160 2019-07-08 CERTIFICATE OF PUBLICATION 2019-07-08
190424020043 2019-04-24 ARTICLES OF ORGANIZATION 2019-04-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345262075 0215800 2021-04-21 253 GENESEE STREET, UTICA, NY, 13501
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2021-04-21
Emphasis L: GUTREH, L: LOCALTARG, P: LOCALTARG
Case Closed 2022-01-05

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2021-10-15
Current Penalty 0.0
Initial Penalty 1755.0
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Basement, ceiling area, on or about 4-21-21: Employees were using power that originated in a relocatable power tap (RPT), that was not being used in accordance with the manufacturer's recommendations or as listed and labeled. b) Basement, on concrete floor, on or about 4-21-21: Employees were using a duplex galvanized receptacle box that was lying on the floor and was not being used as "listed and labeled", in that it was not permanently mounted and not being used as designed and for its intended purpose.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2021-10-15
Current Penalty 0.0
Initial Penalty 0.0
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) Basement, quad box below sub panel, off main panel, on or about 4-21-21: Employees were operating various hand-held power tools, cords, etc., powered through extension cords that were not protected by ground fault circuit interrupters (GFCI).
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2021-10-15
Current Penalty 0.0
Initial Penalty 0.0
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Basement, ceiling area, on or about 4-21-21: Employees were using an extension cord that was damaged.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 II
Issuance Date 2021-10-15
Current Penalty 0.0
Initial Penalty 1755.0
Nr Instances 3
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers: a) First floor, main corridor, east end, on or about 4-21-21: Employees were walking/working in the immediate vicinity of three separate floor openings that were not protected, exposing the employees to a fall hazard of 9 feet 7 inches and/or 8 feet 7 inches to the basement below.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2021-10-15
Current Penalty 0.0
Initial Penalty 1755.0
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Stairway between second and third floor, on or about 4-21-21: Employees were using a stairway between the second and third floor that was not equipped with at least one handrail, exposing the employees to a fall hazard of up to 9 feet.