Name: | HOMETOWN CONSTRUCTION LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 05 Jun 2019 (6 years ago) |
Entity Number: | 5565417 |
ZIP code: | 12831 |
County: | Saratoga |
Place of Formation: | New York |
Address: | 235 GURN SPRINGS RD LOT #8, GANESVOORT, NY, United States, 12831 |
Name | Role | Address |
---|---|---|
THE LLC | DOS Process Agent | 235 GURN SPRINGS RD LOT #8, GANESVOORT, NY, United States, 12831 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
191126000737 | 2019-11-26 | CERTIFICATE OF PUBLICATION | 2019-11-26 |
190605000708 | 2019-06-05 | ARTICLES OF ORGANIZATION | 2019-06-05 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
3615345 | TRUSTFUNDHIC | INVOICED | 2023-03-14 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3615386 | RENEWAL | INVOICED | 2023-03-14 | 100 | Home Improvement Contractor License Renewal Fee |
3301500 | TRUSTFUNDHIC | INVOICED | 2021-02-28 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3301501 | RENEWAL | INVOICED | 2021-02-28 | 100 | Home Improvement Contractor License Renewal Fee |
2967154 | RENEWAL | INVOICED | 2019-01-23 | 100 | Home Improvement Contractor License Renewal Fee |
2967153 | TRUSTFUNDHIC | INVOICED | 2019-01-23 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2485001 | RENEWAL | INVOICED | 2016-11-05 | 100 | Home Improvement Contractor License Renewal Fee |
2485000 | TRUSTFUNDHIC | INVOICED | 2016-11-05 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1951507 | RENEWAL | INVOICED | 2015-01-27 | 100 | Home Improvement Contractor License Renewal Fee |
1951506 | TRUSTFUNDHIC | INVOICED | 2015-01-27 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
337734693 | 0213400 | 2012-11-30 | 20 SWEETWATER AVENUE, STATEN ISLAND, NY, 10308 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2013-04-26 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-06-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: On or about 11/30/12 CSHO observed an employee cutting plywood sheathing using a Makita circular saw while not wearing any eye and or face protection. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-04-26 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-06-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above the lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of 29 CFR 1926.502(k) developed and implemented: On or about 11/30/12 CSHO observed an employee working on and from a newly constructed second floor balcony with no fall protection systems in place. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261052 C01 |
Issuance Date | 2013-04-26 |
Current Penalty | 1600.0 |
Initial Penalty | 1600.0 |
Final Order | 2013-06-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with one handrail and one stairrail system along each unprotected side or edge: On or about 11/30/12 CSHO observed an employee enter and exit the building using a stairway with 4 or more risers when it was not equipped with one handrail and one stairrail along each unprotected side or edge. |