Search icon

JIMMYS HOME RENOVATIONS INC

Company Details

Name: JIMMYS HOME RENOVATIONS INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 07 Jun 2019 (6 years ago)
Entity Number: 5566644
ZIP code: 10607
County: Westchester
Place of Formation: New York
Address: 29 FLORENCE AVE, WHITE PLAINS, NY, United States, 10607

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
MANUEL R CAJAMARCA DOS Process Agent 29 FLORENCE AVE, WHITE PLAINS, NY, United States, 10607

History

Start date End date Type Value
2019-06-07 2022-01-26 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
190607010144 2019-06-07 CERTIFICATE OF INCORPORATION 2019-06-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344896246 0216000 2020-08-18 2333 PONDFIELD RD, BRONXVILLE, NY, 10708
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2020-08-18
Emphasis N: SVEP, L: FALL

Related Activity

Type Inspection
Activity Nr 1488611
Safety Yes
Type Accident
Activity Nr 1647091

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2021-02-16
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-03-17
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were exposed to fall hazards due to the Roof Bracket Scaffold not being inspected for visible defects by a competent person before each work shift. a) On or about August 18, 2020, three employees were exposed to fall hazards due to the Ladder Jack Scaffold not being inspected for visible defects by a competent person before each work shift.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2021-02-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-03-17
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were exposed to fall hazards due to the Roof Bracket Scaffold not being erected by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection. b) On or about August 18, 2020, three employees were exposed to fall hazards due to the Ladder Jack Scaffold not being erected by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2021-02-16
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-03-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were exposed to fall and electrical hazards due to the ladder jack scaffold being within a foot of the electrical lines.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261053 B12
Issuance Date 2021-02-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-03-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were exposed to fall and electrical hazards due to the ladder being within a foot of the electrical lines.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2021-02-16
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-03-17
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were expose to fall hazard of approximately 24ft while working on a roof bracket scaffold without the use of fall protection. b) On or about August 18, 2020, three employees were expose to fall hazard of approximately 20ft. while working on Ladder Jack Scaffold without the use of fall protection.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260452 K01
Issuance Date 2021-02-16
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-03-17
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m) Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were using a ladder jack Scaffold that exceeded over 20 feet to conduct roofing work.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260452 K04
Issuance Date 2021-02-16
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-03-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(4): Ladders used to support ladder jacks were not placed, fastened, or equipped with devices to prevent slipping: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees using extension ladder were exposed to fall hazards because extension ladder anti-slip shoe was flipped up causing extension ladder to be unstable for use.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260452 K05
Issuance Date 2021-02-16
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-03-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(k)(5): Scaffold platforms were bridged on to another: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were expose to a fall hazard of approximately 20ft due to two platforms for the Ladder Jack Scaffold being bridged together.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2021-02-16
Abatement Due Date 2021-03-12
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-03-17
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were expose to a fall hazard of approximately 24ft. due to using Roof Bracket Scaffold without training. b) On or about August 18, 2020, three employees were expose to a fall hazard of approximately 20ft. due to using Ladder Jack Scaffold without training.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2021-02-16
Abatement Due Date 2021-03-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-03-17
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, two employees were expose to a fall hazard of approximately 24ft. while erecting a Roof Bracket Scaffold without the adequate training. b) On or about August 18, 2020, two employees were expose to a fall hazard of approximately 20ft. while erecting a Ladder Jack Scaffold without the adequate training.
Citation ID 01008
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2021-02-16
Abatement Due Date 2021-03-12
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2021-03-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were expose to fall hazards due to not being adequately trained on how to use a ladder which would enable each employee to recognize hazards related to ladders.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2021-02-16
Abatement Due Date 2021-03-12
Current Penalty 27306.0
Initial Penalty 27306.0
Final Order 2021-03-17
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were exposed to fall hazards due to working on a roof, approximately 24ft, without fall protection.
Citation ID 03001
Citaton Type Repeat
Standard Cited 19261053 B01
Issuance Date 2021-02-16
Current Penalty 5852.0
Initial Penalty 5852.0
Final Order 2021-03-17
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Location: 233 Pondfield Rd Bronxville NY 10708 a) On or about August 18, 2020, three employees were expose to fall hazards due to using a ladder, for access to a 24ft residential roof that extended approximately a foot above the bracket scaffold level. The Jimmy's Home Renovations, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.1053(b)(1), which was contained in OSHA inspection number 1446948, citation number 1, item number 2 and was affirmed as a final order on 02/25/2020, with respect to a workplace located at 320 Pennsylvania Avenue Tuckahoe, NY 10707.