Search icon

DANIEL EXTERIORS LLC

Company Details

Name: DANIEL EXTERIORS LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 30 Jul 2019 (6 years ago)
Entity Number: 5595616
ZIP code: 14612
County: Monroe
Place of Formation: New York
Address: 250 HAMPTON BLVD, ROCHESTER, NY, United States, 14612

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 250 HAMPTON BLVD, ROCHESTER, NY, United States, 14612

Filings

Filing Number Date Filed Type Effective Date
190730010207 2019-07-30 ARTICLES OF ORGANIZATION 2019-07-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344436266 0213600 2019-11-05 2375 SHERIDAN DRIVE, TONAWANDA, NY, 14150
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-11-06
Emphasis L: FALL, P: FALL
Case Closed 2023-03-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2019-11-14
Current Penalty 600.0
Initial Penalty 1705.0
Contest Date 2019-12-03
Final Order 2020-05-26
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 11/5/19 at a roof project located at 2355 Sheridan Drive, Tonawanda, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2019-11-14
Current Penalty 800.0
Initial Penalty 2273.0
Contest Date 2019-12-03
Final Order 2020-05-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) On or about 11/5/19 at a roof project located at 2355 Sheridan Drive, Tonawanda, New York; employees were using a ladder jack scaffold, with the scaffold brackets and platform to the outside of the supporting ladders. The employees accessed the platform by climbing the supporting ladders and climbing around the bracket and platform. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2019-11-14
Current Penalty 800.0
Initial Penalty 2273.0
Contest Date 2019-12-03
Final Order 2020-05-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 11/5/19 at a roof project located at 2355 Sheridan Drive, Tonawanda, New York; employees performing roofing activities from a ladder jack scaffold approximately 13 feet high were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2019-11-14
Current Penalty 800.0
Initial Penalty 2273.0
Contest Date 2019-12-03
Final Order 2020-05-26
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 11/5/19 at a roof project located at 2355 Sheridan Drive, Tonawanda, New York; employees working on the roof were placing ice and water shield on the roof of a single story building. The roof had a 12 in 12 pitch and an eave heights of approximately 15 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED

Date of last update: 06 Mar 2025

Sources: New York Secretary of State