Search icon

E20 STUCCO INC

Company Details

Name: E20 STUCCO INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 23 Aug 2019 (6 years ago)
Entity Number: 5609641
ZIP code: 11228
County: Kings
Place of Formation: New York
Address: 63 BAY 10 STREET, BROOKLYN, NY, United States, 11228

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
FRANCISCO LOPEZ DOS Process Agent 63 BAY 10 STREET, BROOKLYN, NY, United States, 11228

Filings

Filing Number Date Filed Type Effective Date
190823020056 2019-08-23 CERTIFICATE OF INCORPORATION 2019-08-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345422612 0215000 2021-07-14 2107 EAST 7 STREET, BROOKLYN, NY, 11232
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-07-14
Emphasis L: LOCALTARG, P: LOCALTARG

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2022-01-13
Current Penalty 3218.0
Initial Penalty 3218.0
Final Order 2022-02-08
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): Location: 2107 East 7th Street, Brooklyn, NY 11223 On or about: July 14, 2021 (a) Employees working on the first tier of a 4-tier supported frame scaffold that was not fully planked or decks; employees were performing stucco work on the exterior wall.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2022-01-13
Current Penalty 3218.0
Initial Penalty 3218.0
Final Order 2022-02-08
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Location: 2107 East 7th Street, Brooklyn, NY 11223 On or about: July 14, 2021 (a) The employer did not ensure that safe means of access were provided for each employee; employees performing stucco work climbed scaffold frames to access their working levels.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2022-01-13
Current Penalty 2575.0
Initial Penalty 2575.0
Final Order 2022-02-08
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2):All brace connections were not secured. Location: 2107 East 7th Street, Brooklyn, NY 11223 On or about: July 14, 2021 (a) Employees working on the first tier of a 4-tier supported frame scaffold that was not fully braced by cross braces; employees were performing stucco work on the exterior wall.
344377171 0215000 2019-10-15 1714 BAY RIDGE PARKWAY, BROOKLYN, NY, 11204
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-10-15
Emphasis P: FALL, L: FALL
Case Closed 2022-07-21

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2019-11-08
Current Penalty 1990.0
Initial Penalty 3978.0
Contest Date 2020-03-18
Final Order 2020-06-18
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Location: a) Supported scaffold on first floor northeast side of the jobsite: On or about 10/15/2019, employees were installing stuccos and painting on the third tier platform of a four-tier-high supported scaffold that was not fully planked or decked between front upright and the guardrail supports, and were exposed to falling approximately 18 feet to the lower level.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2019-11-08
Current Penalty 1420.0
Initial Penalty 2842.0
Contest Date 2020-03-18
Final Order 2020-06-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement Location: a) Supported scaffold on first floor of the jobsite: On or about 10/15/2019, employees were installing stuccos and painting on the third tier platform of a four-tier-high supported scaffold. The supported scaffold uprights were not braced to prevent swaying and displacement.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2019-11-08
Current Penalty 1420.0
Initial Penalty 2842.0
Contest Date 2020-03-18
Final Order 2020-06-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Scaffold frames were used as a means of access. Location: a) Supported scaffold on first floor northeast side of the jobsite: On or about 10/15/2019, employees climbed the scaffold frames and crossbraces as a mean of access between the third tier platform of a four-tier-high supported scaffold to the first floor level.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2019-11-08
Current Penalty 0.0
Initial Penalty 3978.0
Contest Date 2020-03-18
Final Order 2020-06-18
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: a) Supported scaffold on first floor northeast side of the jobsite On or about 10/15/2019, employees were installing stuccos and painting on the third tier platform of a four-tier-high supported scaffold, and were exposed to falling approximately 18 feet to the lower level.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2019-11-08
Current Penalty 1990.0
Initial Penalty 3978.0
Contest Date 2020-03-18
Final Order 2020-06-18
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: a) On the roof of the building: On or about 10/15/2019, an employee was installing stuccos and painting on the roof of the building and was exposed to falling approximately 10 feet to the lower level. Employee was not protected by the use of guardrails, safety nets, or personal fall arrest systems.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2019-11-08
Current Penalty 1680.0
Initial Penalty 3410.0
Contest Date 2020-03-18
Final Order 2020-06-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed. Location: a) On the front porch roof level of the jobsite: On or about 10/15/2019, an employee used a folded A-frame ladder as a mean to install stucco and was exposed to falling. The ladder was not designed to be used while folded. Location: b) On the ground level of the jobsite: On or about 10/15/2019, employees painted while standing on top of a plank, which was supported on one side by a step of an A-frame ladder and supported on the other side by the base of the handrail for the front entrance staircase. The ladder is not designed to be use for this purpose.

Date of last update: 23 Mar 2025

Sources: New York Secretary of State