Name: | JCA HOME IMPROVEMENT NY CORP |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 23 Sep 2019 (6 years ago) |
Entity Number: | 5625785 |
ZIP code: | 06704 |
County: | Westchester |
Place of Formation: | New York |
Address: | 75 HARPERS FERRY RD, WATERBURY, CT, United States, 06704 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | JCA HOME IMPROVEMENT NY CORP, CONNECTICUT | 1341195 | CONNECTICUT |
Name | Role | Address |
---|---|---|
SANDRO GUERRERO | DOS Process Agent | 75 HARPERS FERRY RD, WATERBURY, CT, United States, 06704 |
Name | Role | Address |
---|---|---|
SANDRO GUERRERO | Chief Executive Officer | 75 HARPERS FERRY, WATERBURY, CT, United States, 06704 |
Start date | End date | Type | Value |
---|---|---|---|
2019-09-23 | 2023-06-07 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2019-09-23 | 2023-06-07 | Address | 11 ROOSEVELT STREET, WHITE PLAINS, NY, 10605, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
230607003209 | 2023-06-07 | BIENNIAL STATEMENT | 2021-09-01 |
190923010224 | 2019-09-23 | CERTIFICATE OF INCORPORATION | 2019-09-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346289705 | 0216000 | 2022-10-18 | 8 S. LAWN AVENUE, ELMSFORD, NY, 10523 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2022-10-28 |
Current Penalty | 5470.0 |
Initial Penalty | 5470.0 |
Final Order | 2022-12-14 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets. A) 8 S. Lawn Avenue, Elmsford - NY: Employees were exposed to head injuries while working below other employees that were working above them on a scaffold. The employees below were not protected by hard hats or any other type of head protection, on or about October 18th, 2022. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 C03 |
Issuance Date | 2022-10-28 |
Current Penalty | 4558.0 |
Initial Penalty | 4558.0 |
Final Order | 2022-12-14 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement. A) 8 S. Lawn Avenue, Elmsford - NY: Employees were exposed to fall /scaffold collapse hazards of approximately 20 feet while working on a pump jack scaffold that was not braced at the bottom. The employees were not wearing any type of fall protection either, on or about October 18th, 2022 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2022-10-28 |
Current Penalty | 6381.0 |
Initial Penalty | 6381.0 |
Final Order | 2022-12-14 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. A) 8 S. Lawn Avenue, Elmsford - NY: Employees were exposed to fall hazards of approximately 20 feet while working on a pump jack scaffold that was provided with a complete guardrail system, not were the employees wearing any fall protection devices, on or about October 18th, 2022 |