Name: | JCM CONSTRUCTION INC |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 10 Dec 2019 (5 years ago) |
Entity Number: | 5669230 |
ZIP code: | 11374 |
County: | Queens |
Place of Formation: | New York |
Address: | 6115 97TH STREET, APT 7L, REGO PARK, NY, United States, 11374 |
Contact Details
Phone +1 718-500-2469
Phone +1 631-569-5424
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
JACQUELINE PEREZ | DOS Process Agent | 6115 97TH STREET, APT 7L, REGO PARK, NY, United States, 11374 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
2094421-DCA | Inactive | Business | 2020-02-11 | 2023-02-28 |
1376353-DCA | Inactive | Business | 2010-11-05 | 2011-06-30 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
191210010280 | 2019-12-10 | CERTIFICATE OF INCORPORATION | 2019-12-10 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
3284813 | RENEWAL | INVOICED | 2021-01-18 | 100 | Home Improvement Contractor License Renewal Fee |
3284812 | TRUSTFUNDHIC | INVOICED | 2021-01-18 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3167626 | LICENSEDOC0 | INVOICED | 2020-03-09 | 0 | License Document Replacement, Lost in Mail |
3148407 | LICENSE | INVOICED | 2020-01-24 | 75 | Home Improvement Contractor License Fee |
3148406 | TRUSTFUNDHIC | INVOICED | 2020-01-24 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3148145 | FINGERPRINT | INVOICED | 2020-01-24 | 75 | Fingerprint Fee |
1030090 | FINGERPRINT | INVOICED | 2010-11-05 | 75 | Fingerprint Fee |
1030089 | TRUSTFUNDHIC | INVOICED | 2010-11-05 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1030088 | LICENSE | INVOICED | 2010-11-05 | 50 | Home Improvement Contractor License Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345244594 | 0213600 | 2021-04-03 | 185 SOUTH TRANSIT ROAD, EAST AMHERST, NY, 14051 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2021-06-04 |
Current Penalty | 1492.0 |
Initial Penalty | 1492.0 |
Final Order | 2021-06-30 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 4/3/21, at the roof area of the site, Lockport, NY. Portable ladders, used to access the roof, did not extend side rails at least 3 feet above the upper landing surface being accessed. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19261053 B04 |
Issuance Date | 2021-06-04 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-06-30 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about 4/3/21, at the back entrance area of the site, Lockport, NY. Employee leaned a 6-foot step ladder against the wall and stepped two-step up. Ladder was used for purposes other than the purpose for which they were designed. NO ABATEMENT CERTIFICATION REQUIRED |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2021-03-22 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2025-01-30 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2021-06-08 |
Current Penalty | 2487.0 |
Initial Penalty | 2487.0 |
Final Order | 2021-07-02 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 3/22/2021 at a roof project located at 6540 Main Street, Williamsville, New York; employees were replacing the roof of a two story building. The roof had an 5 in 12 pitch and an eave height of approximately 22 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260100 A |
Issuance Date | 2021-06-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-07-02 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 3/22/2021 at a roof project located at 6540 Main Street, Williamsville, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED |