Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346705858 | 0216000 | 2023-05-15 | 20 FRANCIS PLACE, MONSEY, NY, 10952 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260025 A |
Issuance Date | 2023-08-31 |
Current Penalty | 1280.25 |
Initial Penalty | 1707.0 |
Final Order | 2023-09-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: location: basement on or about: 5/15/23 a) An employee was engaged in residential plumbing work. There was debris, including but not limited to, scrap lumber with protruding nails in the work area. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19261052 A06 |
Issuance Date | 2023-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-09-26 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(a)(6): All parts of stairways were not free of hazardous projections, such as protruding nails: location: stairs between basement and first floor on or about: 5/15/23 a) Employees were engaged in residential plumbing work. There was debris, including but not limited to, scrap lumber with protruding nails in the stairway. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19261052 A07 |
Issuance Date | 2023-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-09-26 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(a)(7): Slippery conditions on stairways were not eliminated before the stairways were used to reach other levels: location: stairs between basement and first floor on or about: 5/15/23 a) Employees were engaged in residential plumbing work. There was debris, including but not limited to, plastic packaging in the stairway. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01001D |
Citaton Type | Serious |
Standard Cited | 19261053 B09 |
Issuance Date | 2023-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-09-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear. location: basement on or about: 5/15/23 a) An employee was using an A frame ladder while engaged in residential plumbing work. The area around the base of the ladder was covered with debris. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261052 C01 I |
Issuance Date | 2023-08-31 |
Current Penalty | 1280.25 |
Initial Penalty | 1707.0 |
Final Order | 2023-09-26 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: location: stairs between 1st floor and basement on or about: 5/15/23 a) Employees used the stairway for access between the 1st floor and basement. The 9'6" high stairway did not have a handrail. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |