Search icon

BEAST CONSTRUCTION, LLC

Company Details

Name: BEAST CONSTRUCTION, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 21 Jan 2020 (5 years ago)
Entity Number: 5692618
ZIP code: 13057
County: Onondaga
Place of Formation: New York
Address: 7099 EAST TAFT ROAD, EAST SYRACUSE, NY, United States, 13057

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 7099 EAST TAFT ROAD, EAST SYRACUSE, NY, United States, 13057

History

Start date End date Type Value
2020-01-21 2020-03-02 Address 7098 EAST TAFT ROAD, EAST SYRACUSE, NY, 13047, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
200603000330 2020-06-03 CERTIFICATE OF PUBLICATION 2020-06-03
200302000758 2020-03-02 CERTIFICATE OF CHANGE 2020-03-02
200121000392 2020-01-21 ARTICLES OF ORGANIZATION 2020-01-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345845010 0215800 2022-03-21 630 WEST BRIGHTON AVENUE, SYRACUSE, NY, 13207
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-03-21
Emphasis L: FALL
Case Closed 2024-09-23

Related Activity

Type Complaint
Activity Nr 1877034
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2022-05-06
Current Penalty 24861.0
Initial Penalty 24861.0
Contest Date 2022-06-22
Final Order 2022-12-19
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a) 630 West Brighton Avenue, Syracuse, NY 13207: On or about, March 21, 2022, employees working on the roof of a house, with a low-slope were not provided any means of fall protection.
345381180 0215800 2021-06-25 103 GLENDALE ROAD, NORTH SYRACUSE, NY, 13212
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2021-06-25
Emphasis L: FALL
Case Closed 2023-01-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2021-12-16
Current Penalty 0.0
Initial Penalty 4505.0
Contest Date 2022-10-03
Final Order 2022-11-18
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 103 Glendale Road, North Syracuse, NY 13212, on or about 6/25/21: Workers were installing a roof system onto a single story residence, with a 5:12 pitch and a ground to eave height of 10 feet where they accessed the roof with a ladder that did not extend at least 3 feet above the upper landing.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2021-12-16
Current Penalty 0.0
Initial Penalty 9011.0
Contest Date 2022-10-03
Final Order 2022-11-18
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 103 Glendale Road, North Syracuse, NY 13212, on or about 6/25/21: Workers were installing a roof system onto a single story residence, with a 5:12 pitch and a ground to eave height of 10 feet without fall protection of any kind. Beast Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 1498815, citation number 2, item number 1 and was affirmed as a final order on 3/23/21, with respect to a workplace located at 1801 &1803 Bellevue Avenue, Syracuse, NY 13207.
344988159 0215800 2020-10-22 1801 & 1803 BELLEVUE AVENUE, SYRACUSE, NY, 13207
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2020-10-22
Emphasis L: FALL
Case Closed 2023-01-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2021-02-25
Abatement Due Date 2021-03-05
Current Penalty 0.0
Initial Penalty 4096.0
Contest Date 2021-05-10
Final Order 2022-11-18
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) At the jobsite, on the scaffold, on or about 10/22/20: Workers access and egressed the scaffold platform by climbing over the pick and pick bracket support.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2021-02-25
Abatement Due Date 2021-03-05
Current Penalty 0.0
Initial Penalty 4096.0
Contest Date 2021-05-10
Final Order 2022-11-18
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) At the jobsite, on or about 10/22/20: Employees were working on an aluminum ladder-jack scaffold where that scaffold was within 6 inches of a live power supply line.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2021-02-25
Abatement Due Date 2021-03-05
Current Penalty 0.0
Initial Penalty 4096.0
Contest Date 2021-05-10
Final Order 2022-11-18
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. a) At the worksite, on the scaffold, on or about 10/22/20: Roofers worked on a ladder jack scaffold, where the pick surface was approximately 19 feet from ground and where no fall protection was provided.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2021-02-25
Abatement Due Date 2021-03-05
Current Penalty 0.0
Initial Penalty 27306.0
Contest Date 2021-05-10
Final Order 2022-11-18
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) NOTE TO CSHO: USE THIS OPTION ONLY IN CASES WHERE THE INFEASIBILITY/GREATER HAZARD EXCEPTION IS NOT IN ISSUE. a) At the jobsite, on or about 10/22/20: Workers were installing roofing material on a 8:12 pitch roof, with a ground to eave height of 24 feet, without fall protection of any kind.

Date of last update: 23 Mar 2025

Sources: New York Secretary of State