Filing Number Date Filed Type Effective Date
200131010433 2020-01-31 CERTIFICATE OF INCORPORATION 2020-01-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347273849 0216000 2024-02-08 1738 CROTONA PARK EAST, BRONX, NY, 10460
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2024-02-12
Emphasis N: FALL

Related Activity

Type Complaint
Activity Nr 2130086
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260025 A
Issuance Date 2024-03-19
Current Penalty 1000.0
Initial Penalty 2765.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: location: roof on or about: 2/8/24 a) Employees, engaged in masonry work, had to climb over debris that was located throughout their work area. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2024-03-19
Current Penalty 2000.0
Initial Penalty 3687.0
Final Order 2024-04-15
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: location: roof on or about: 2/8/24 a) An employee was using a Bosch right angle grinder to cut block. The grinder was missing a guard for the cutting wheel. location: roof on or about: 2/8/24 b) An employee was using a Bosch right angle grinder to cut tile. The grinder was missing a guard for the cutting disc. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2024-03-19
Current Penalty 2500.0
Initial Penalty 4610.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors: location: roof on or about: 2/8/24 a) An employee was using electrical equipment, including a DeWalt angle grinder, while engaged in masonry work. The employee was not provided with GFCI protection or an assured equipment grounding conductor program. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2024-03-19
Current Penalty 1500.0
Initial Penalty 2765.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: location: roof on or about: 2/8/24 a) An employee was using electrical equipment, including a DeWalt angle grinder, while engaged in masonry work. The extension cord was not provided with strain relief. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2024-03-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-15
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: location: roof on or about: 2/8/24 a) An employee was using electrical equipment, including a DeWalt angle grinder, while engaged in masonry work. An extension cord that was being used was missing the insulation, exposing the metal wire. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B09 I
Issuance Date 2024-03-19
Current Penalty 3500.0
Initial Penalty 6452.0
Final Order 2024-04-15
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(9)(i): Each employee performing overhand bricklaying and related work 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a controlled access zone: location: roof on or about: 2/8/24 a) Employees, laying bricks and stone, were not using fall protection. The employees were exposed to a fall of 40 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.

Date of last update: 23 Mar 2025