Search icon

KENNY'S RENOVATIONS INC

Company Details

Name: KENNY'S RENOVATIONS INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 27 Feb 2020 (5 years ago)
Date of dissolution: 18 Dec 2024
Entity Number: 5717883
ZIP code: 10940
County: Orange
Place of Formation: New York
Address: 42 excelsior ave, MIDDLETOWN, NY, United States, 10940

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
KENNY'S RENOVATIONS INC DOS Process Agent 42 excelsior ave, MIDDLETOWN, NY, United States, 10940

History

Start date End date Type Value
2022-12-01 2024-12-18 Address 42 excelsior ave, MIDDLETOWN, NY, 10940, USA (Type of address: Service of Process)
2022-11-29 2024-12-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2020-02-27 2022-11-29 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2020-02-27 2022-12-01 Address 6 GRANT STREET, MIDDLETOWN, NY, 10940, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
241218003727 2024-12-18 CERTIFICATE OF DISSOLUTION-CANCELLATION 2024-12-18
221201000302 2022-11-29 CERTIFICATE OF CHANGE BY ENTITY 2022-11-29
200227010483 2020-02-27 CERTIFICATE OF INCORPORATION 2020-02-27

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345677975 0213100 2021-10-06 92 OLD GLENHAM RD., BEACON, NY, 12508
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2021-10-06
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2022-03-08
Abatement Due Date 2022-04-08
Current Penalty 4351.0
Initial Penalty 4351.0
Contest Date 2022-03-31
Final Order 2022-11-12
Nr Instances 6
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who was exposed to fall hazards: Location: entire site On or about: 10/6/21 a) Employees, exposed to a fall hazard while engaged in roofing and carpentry work, were not provided with fall protection training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B13
Issuance Date 2022-03-08
Current Penalty 29005.0
Initial Penalty 29005.0
Contest Date 2022-03-31
Final Order 2022-11-12
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems: Location: roof On or about: 10/6/21 a) Employees, engaged in residential roofing and carpentry, were not using any means of fall protection. The employees were exposed to a fall between 16 and 19 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.

Date of last update: 23 Mar 2025

Sources: New York Secretary of State