Search icon

HURRICANE-14 CONSTRUCTION CORP

Company Details

Name: HURRICANE-14 CONSTRUCTION CORP
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 04 Mar 2020 (5 years ago)
Entity Number: 5721103
ZIP code: 11977
County: Suffolk
Place of Formation: New York
Address: 34 LAKESIDE LANE, WESTHAMPTON, NY, United States, 11977

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
PIERRE GAGNE DOS Process Agent 34 LAKESIDE LANE, WESTHAMPTON, NY, United States, 11977

Filings

Filing Number Date Filed Type Effective Date
200304020031 2020-03-04 CERTIFICATE OF INCORPORATION 2020-03-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341433019 0214700 2016-04-28 116 MEETING HOUSE RD., QUOGUE, NY, 11959
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2016-04-28
Case Closed 2016-04-28

Related Activity

Type Inspection
Activity Nr 1106013
Safety Yes
341060135 0214700 2015-11-16 116 MEETING HOUSE RD., QUOGUE, NY, 11959
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2015-11-16
Emphasis L: FALL, N: AMPUTATE, P: FALL
Case Closed 2017-01-09

Related Activity

Type Inspection
Activity Nr 1106017
Safety Yes
Type Inspection
Activity Nr 1143301
Safety Yes
Type Inspection
Activity Nr 1106009
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2016-01-20
Abatement Due Date 2016-01-28
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2016-02-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Worksite: An employee was cutting exterior window trim using a DeWalt table saw (serial no. 2014 12-CT28639). The exposed portion of the unguarded blade was approximately 2" above the table; on or about 11/16/15. The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
339923534 0214700 2014-08-27 137 DUNE RD, WESTHAMPTON BEACH, NY, 11978
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-08-27
Emphasis L: FALL, P: FALL
Case Closed 2019-03-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-09-19
Abatement Due Date 2014-10-01
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite: Employees doing roofing work and working directly under ongoing roofing work were not using head protection; on or about 8/27/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2014-09-19
Abatement Due Date 2014-10-01
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Worksite: Employees using saw tools to cut lattice were not provided with eye protection; on or about 8/27/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02 IV
Issuance Date 2014-09-19
Abatement Due Date 2014-10-01
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms without being specifically designed by the manufacturer for such use: a) Worksite: An employee installing lattice on a roof from a Caterpillar TH83 rough terrain forklift approximately 22 ft. above the ground was working from a scaffold platform attached to the forks which were not approved or designed by the manufacturer for such use; on or about 8/27/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-09-19
Abatement Due Date 2014-10-01
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-10-15
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite: An employee installing lattice on a roof from a scaffold platform approximately 24 ft. above the ground was not using fall protection; on or about 8/27/2014. b) Worksite: An employee installing lattice on a roof from a Caterpillar TH83 rough terrain forklift approximately 22 ft. above the ground was working from a scaffold platform and was not using fall protection; on or about 8/27/2014. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-09-19
Abatement Due Date 2014-10-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-10-15
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) Worksite: An employee installing lattice on a roof from a scaffold platform approximately 24 ft. above the ground had not been trained in scaffold safety, including fall protection training; on or about 8/27/2014. b) Worksite: An employee installing lattice on a roof from a Caterpillar TH83 rough terrain forklift approximately 22 ft. above the ground was working from a scaffold platform and had not been trained in scaffold safety, including fall protection training; on or about 8/27/2014. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260602 D
Issuance Date 2014-09-19
Abatement Due Date 2014-10-23
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178: a) Worksite: Employees operating the Caterpillar TH83 rough terrain forklift did not receive training, on or about, 08/27/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 23 Mar 2025