Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-01-11
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2022-07-01 |
Abatement Due Date |
2022-08-18 |
Current Penalty |
4351.0 |
Initial Penalty |
4351.0 |
Final Order |
2022-07-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a) 159 Lexi Lane, Baldwinsville, NY 13027, on or about 1/11/22: Employees worked from the deck of a pump jack scaffold, 16 feet from ground without complete guard rails at the ends, without a midrail, and where a pick cantilevered in excess of 18 inches from its support. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 B05 II |
Issuance Date |
2022-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-07-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: a) 159 Lexi Lane, Baldwinsville, NY 13027, on or about 1/11/22: Employees worked from the deck of a pump jack scaffold, 16 feet from ground where the pick extended past its support by approximately 5 feet and where guardrails were not installed to prevent access. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2022-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-07-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) 159 Lexi Lane, Baldwinsville, NY 13027, on or about 1/11/22: Employees worked from the deck of a pump jack scaffold, 16 feet from ground without complete guard rails at the ends. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 III |
Issuance Date |
2022-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-07-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(iii): Midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members were not installed between the top edge of the guardrail system and the scaffold platform. a) 159 Lexi Lane, Baldwinsville, NY 13027, on or about 1/11/22: Employees worked from the deck of a pump jack scaffold, 16 feet from ground without a midrail or equivalent. |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19260452 J02 |
Issuance Date |
2022-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-07-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) 159 Lexi Lane, Baldwinsville, NY 13027, on or about 1/11/22: Employees worked from the deck of a pump jack scaffold, 16 feet from ground without bracing at the bottom portion of the uprights. |
|
|