Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-06-11
|
Related Activity
Type |
Accident |
Activity Nr |
1774074 |
|
Type |
Inspection |
Activity Nr |
1534495 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2021-11-29 |
Abatement Due Date |
2021-12-09 |
Current Penalty |
12287.0 |
Initial Penalty |
13653.0 |
Contest Date |
2022-01-03 |
Final Order |
2022-05-31 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to the work environment to control or eliminate any hazards or other exposure to illness or injury. a) At the vicinity of 6820 Cold Brook Road, Scott, NY ., on or about June 1, 2021 and thereafter: The employer did not train workers to recognize and avoid dangers related when working at or near water. Workers were required to swim across a pond, resulting in the drowning of a worker. b) At the vicinity of 6820 Cold Brook Road, Scott, NY ., on or about June 1, 2021 and thereafter: The employer did not train workers to recognize and avoid electrical hazards when installing fiber optic lines on pre-existing electrical poles . Work was performed within 5 feet of 4.8 KV overhead electrical lines without any protective controls in place. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260028 A |
Issuance Date |
2021-11-29 |
Abatement Due Date |
2021-12-09 |
Current Penalty |
12287.0 |
Initial Penalty |
13653.0 |
Contest Date |
2022-01-03 |
Final Order |
2022-05-31 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions. a) At the vicinity of 6820 Cold Brook Road, Scott, NY., on or about June 2, 2021: Employees were exposed to drowning hazards as they were not provided with personal floatation devices when required to cross a pond to install fiber optic lines. b) At the vicinity of 6820 Bold Brook Road, Scott, NY., on or about June 1, 2021: Employees were exposed to drowning hazards as they were not provided with personal flotation devices when required to cross a pond to install fiber optic lines. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260050 C |
Issuance Date |
2021-11-29 |
Abatement Due Date |
2021-12-09 |
Current Penalty |
12287.0 |
Initial Penalty |
13653.0 |
Contest Date |
2022-01-03 |
Final Order |
2022-05-31 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.50(c): In the absence of an infirmary, clinic, hospital, or physician, that is reasonably accessible in terms of time and distance to the worksite, which is available for the treatment of injured employees, a person who has a valid certificate in first-aid training from the U.S. Bureau of Mines, the American Red Cross, or equivalent training that can be verified by documentary evidence, was not available at the worksite to render first aid: a) At the vicinity of 6820 Cold Brook Road, Scott, NY, on or about June 1, 2021 and thereafter: The employer did not have a person who was certified in first aid training (which includes Basic First Aid and CPR) available to render first aid. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260097 C02 II |
Issuance Date |
2021-11-29 |
Abatement Due Date |
2021-12-09 |
Current Penalty |
3687.0 |
Initial Penalty |
4096.0 |
Contest Date |
2022-01-03 |
Final Order |
2022-05-31 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.97(c)(2)(ii): The employer did not ensure insulating equipment was inspected for damage before each day's use and immediately following any incident that can reasonably be suspected of causing damage. Insulating gloves were not air tested, along with the inspection. a) At the vicinity of 6820 Cold Brook Road, Scott, NY., on or about June 1, 2021: Employees were exposed to electrical hazards as the provided insulated gloves were not inspected before each day's use . Employees were installing fiber optic cable within 5 feet of overhead 4.8KV energized lines. b) At the vicinity of 6820 Cold Brook Road, Scott, NY., on or about June 2, 2021: Employees were exposed to electrical hazards as the provided insulated gloves were not inspected before each day's use . Employees were installing fiber optic cable within 5 feet of overhead 4.8KV energized lines. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260416 A01 |
Issuance Date |
2021-11-29 |
Abatement Due Date |
2021-12-09 |
Current Penalty |
3687.0 |
Initial Penalty |
4096.0 |
Contest Date |
2022-01-03 |
Final Order |
2022-05-31 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(a)(1): The employer permitted work in proximity to electric power circuits that were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) At the vicinity of 6820 Cold Brook Road, Scott, NY., on or about June 1, 2021: Workers installed fiber optic lines on pre-existing electrical poles, while exposed to electrical hazards. The work was performed within 5 feet of 4.8 KV overhead electrical lines without any protective controls in place. b) At the vicinity of 6820 Cold Brook Road, Scott, NY., on or about June 2, 2021: Workers installed fiber optic lines on pre-existing electrical poles, while exposed to electrical hazards. The work was performed within 5 feet of 4.8 KV overhead electrical lines without any protective controls in place. |
|
|