Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-11-11
|
Emphasis |
N: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1709815 |
Safety |
Yes |
|
Type |
Accident |
Activity Nr |
2101926 |
|
Type |
Inspection |
Activity Nr |
1709991 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260251 A01 |
Issuance Date |
2024-05-10 |
Abatement Due Date |
2024-06-06 |
Current Penalty |
3687.0 |
Initial Penalty |
3687.0 |
Contest Date |
2024-05-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Exterior wall panel lifted by two nylon slings, Lift-All brand EE2-804D. One of the nylon straps had observable damage and fraying of the material. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260251 E08 II |
Issuance Date |
2024-05-10 |
Abatement Due Date |
2024-06-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2024-05-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.251(e)(8)(ii): Melting or charring of any part of the sling surface. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Exterior wall panel lifted by two nylons slings, Lift-All brand EE2-804D. One of the nylon straps had observable melting or charred damage on the side. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260251 E08 IV |
Issuance Date |
2024-05-10 |
Abatement Due Date |
2024-06-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2024-05-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.251(e)(8)(iv): Synthetic web slings with broken or worn stitches were not immediately removed from service. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Exterior wall panel lifted by two nylon slings, Lift-All brand EE2-804D. One of the nylon straps had observable damage and fraying of the material. Sling was not removed from service. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260251 E04 II |
Issuance Date |
2024-05-10 |
Abatement Due Date |
2024-06-06 |
Current Penalty |
3687.0 |
Initial Penalty |
3687.0 |
Contest Date |
2024-05-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.251(e)(4)(ii): Nylon slings were not kept free of all sharp edges that could in any way damage the webbing On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Two nylon slings were placed into openings of a steel frame for exterior wall panels with metal screws pointed towards one the slings. The opening of the steel frame appeared to be sharp and the metal screws could rub against the slings when hoisted upwards by the crane. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261052 B01 |
Issuance Date |
2024-05-10 |
Abatement Due Date |
2024-06-06 |
Current Penalty |
6452.0 |
Initial Penalty |
6452.0 |
Contest Date |
2024-05-30 |
Nr Instances |
1 |
Nr Exposed |
16 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Interior pan staircase near eastern side of the building leading from the 1st floor to the 5th floor were not filled with concrete or temporarily fitted with wood or other solid material. Workers exposed to a trip and fall hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2024-05-10 |
Abatement Due Date |
2024-06-06 |
Current Penalty |
6452.0 |
Initial Penalty |
6452.0 |
Contest Date |
2024-05-30 |
Nr Instances |
1 |
Nr Exposed |
16 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Interior stairway near eastern side of the building leading from the 1st floor to the 5th floor were not installed with handrail(s) for the workers. Workers exposed to trip and fall hazards. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2024-05-10 |
Abatement Due Date |
2024-06-06 |
Current Penalty |
16131.0 |
Initial Penalty |
16131.0 |
Contest Date |
2024-05-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) During erection of exterior cold-formed steel wall panels, three (3) workers were exposed to fall hazards of approximately 60 feet while guiding and anchoring the wall panel on the 5th floor approximately 2-3 feet from the edge. No other fall protection was utilized. |
|
|