Search icon

SPAXEL BUILDERS, LLC

Company Details

Name: SPAXEL BUILDERS, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 15 Jul 2020 (5 years ago)
Entity Number: 5788666
ZIP code: 10003
County: New York
Place of Formation: New York
Address: 228 Park Ave South, #30194, New York, NY, United States, 10003

DOS Process Agent

Name Role Address
SPAXEL BUILDERS, LLC DOS Process Agent 228 Park Ave South, #30194, New York, NY, United States, 10003

History

Start date End date Type Value
2020-07-15 2024-09-18 Address 5 WEST 37TH STREET, 12TH FLOOR, NEW YORK, NY, 10018, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240918003599 2024-09-18 BIENNIAL STATEMENT 2024-09-18
200715010362 2020-07-15 ARTICLES OF ORGANIZATION 2020-07-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347100364 0216000 2023-11-11 16 WADE SQUARE, BRONX, NY, 10457
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2023-11-11
Emphasis N: FALL

Related Activity

Type Inspection
Activity Nr 1709815
Safety Yes
Type Accident
Activity Nr 2101926
Type Inspection
Activity Nr 1709991
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260251 A01
Issuance Date 2024-05-10
Abatement Due Date 2024-06-06
Current Penalty 3687.0
Initial Penalty 3687.0
Contest Date 2024-05-30
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(a)(1): Rigging equipment for material handling was not inspected prior to use on each shift and as necessary during its use to ensure that it was safe. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Exterior wall panel lifted by two nylon slings, Lift-All brand EE2-804D. One of the nylon straps had observable damage and fraying of the material.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260251 E08 II
Issuance Date 2024-05-10
Abatement Due Date 2024-06-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-05-30
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(e)(8)(ii): Melting or charring of any part of the sling surface. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Exterior wall panel lifted by two nylons slings, Lift-All brand EE2-804D. One of the nylon straps had observable melting or charred damage on the side.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260251 E08 IV
Issuance Date 2024-05-10
Abatement Due Date 2024-06-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-05-30
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(e)(8)(iv): Synthetic web slings with broken or worn stitches were not immediately removed from service. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Exterior wall panel lifted by two nylon slings, Lift-All brand EE2-804D. One of the nylon straps had observable damage and fraying of the material. Sling was not removed from service.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260251 E04 II
Issuance Date 2024-05-10
Abatement Due Date 2024-06-06
Current Penalty 3687.0
Initial Penalty 3687.0
Contest Date 2024-05-30
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.251(e)(4)(ii): Nylon slings were not kept free of all sharp edges that could in any way damage the webbing On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Two nylon slings were placed into openings of a steel frame for exterior wall panels with metal screws pointed towards one the slings. The opening of the steel frame appeared to be sharp and the metal screws could rub against the slings when hoisted upwards by the crane.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 B01
Issuance Date 2024-05-10
Abatement Due Date 2024-06-06
Current Penalty 6452.0
Initial Penalty 6452.0
Contest Date 2024-05-30
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Interior pan staircase near eastern side of the building leading from the 1st floor to the 5th floor were not filled with concrete or temporarily fitted with wood or other solid material. Workers exposed to a trip and fall hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2024-05-10
Abatement Due Date 2024-06-06
Current Penalty 6452.0
Initial Penalty 6452.0
Contest Date 2024-05-30
Nr Instances 1
Nr Exposed 16
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) Interior stairway near eastern side of the building leading from the 1st floor to the 5th floor were not installed with handrail(s) for the workers. Workers exposed to trip and fall hazards.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2024-05-10
Abatement Due Date 2024-06-06
Current Penalty 16131.0
Initial Penalty 16131.0
Contest Date 2024-05-30
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. On or about: November 11, 2023 Location: 16 Wade Sq., Bronx, NY 10457 a) During erection of exterior cold-formed steel wall panels, three (3) workers were exposed to fall hazards of approximately 60 feet while guiding and anchoring the wall panel on the 5th floor approximately 2-3 feet from the edge. No other fall protection was utilized.

Date of last update: 22 Mar 2025