Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-12-05
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2020-05-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2020-02-28 |
Current Penalty |
867.5 |
Initial Penalty |
1735.0 |
Final Order |
2020-03-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) West side of parking garage, second level, east end of overpass, on or about 12-5-19: One employee was using a portable, hand-held electric angle grinder equipped with an abrasive wheel, and was not equipped with a protective guard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2020-02-28 |
Current Penalty |
1452.5 |
Initial Penalty |
2892.0 |
Final Order |
2020-03-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) West side of parking garage, second level, east end of overpass, south edge, on or about 12-5-19: One employee was walking/working on an overpass platform without fall protection, exposing the employee to a fall hazard of 16 feet. |
|
|