Name: | JJ HOME IMPROVEMENT 1 CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 20 Aug 2020 (5 years ago) |
Entity Number: | 5817797 |
ZIP code: | 10977 |
County: | Rockland |
Place of Formation: | New York |
Address: | 7 MEMORIAL PARK DR, SPRING VALLEY, NY, United States, 10977 |
Principal Address: | 7 MEMORIAL PARK DRIVE, SPRING VALLEY, NY, United States, 10977 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 7 MEMORIAL PARK DR, SPRING VALLEY, NY, United States, 10977 |
Name | Role | Address |
---|---|---|
SEGUNDO R ALLAICO | Chief Executive Officer | 7 MEMORIAL PARK DRIVE, SPRING VALLEY, NY, United States, 10977 |
Start date | End date | Type | Value |
---|---|---|---|
2020-08-20 | 2023-12-21 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2020-08-20 | 2023-12-21 | Address | 7 MEMORIAL PARK DR, SPRING VALLEY, NY, 10977, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
231221002894 | 2023-12-21 | BIENNIAL STATEMENT | 2023-12-21 |
210428000330 | 2021-04-28 | CERTIFICATE OF AMENDMENT | 2021-04-28 |
200820020166 | 2020-08-20 | CERTIFICATE OF INCORPORATION | 2020-08-20 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347846131 | 0215800 | 2024-10-23 | 5955 - 5965 CALM LAKE LANE, FARMINGTON, NY, 14425 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
347425860 | 0213600 | 2024-04-18 | 224 IDEAL STREET, BUFFALO, NY, 14206 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1742580 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2024-07-24 |
Current Penalty | 3134.0 |
Initial Penalty | 3134.0 |
Final Order | 2024-09-06 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 4/18/2024 at a roof project located at 224 Ideal Street, Buffalo, New York; employees were replacing the roof of a two story house. The roof had an 9 in 12 pitch and an eave height of approximately 16 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-07-24 |
Current Penalty | 2350.0 |
Initial Penalty | 2350.0 |
Final Order | 2024-09-06 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about 4/18/2024 at a roof project located at 224 Ideal Street, Buffalo, New York; an extension ladder was leaned against a wall to access a roof. The top step of the ladder was approximately 1 foot above the landing. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260100 A |
Issuance Date | 2024-07-24 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2024-09-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 4/18/2024 at a roof project located at 224 Ideal Street, Buffalo, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED |