Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-01-04
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2023-05-24 |
Current Penalty |
0.0 |
Initial Penalty |
2678.0 |
Final Order |
2023-06-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. 2 Oneida Street, Rye Brook - NY: An employee was exposed to eye/face injuries while using a pneumatic nail gun. The employees was not protected by eye/face protection, on or about, January 4th, 2023. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-05-24 |
Current Penalty |
4000.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-06-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net systems, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). A) 2 Oneida Street, Rye Brook - NY: Employees were exposed to fall hazards of approximately 30 feet while engaged in roofing work on a residential structure. The employees were not protected by any type of fall protection system, on or about January 4th, 2023. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2023-05-24 |
Current Penalty |
4000.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-06-27 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access: A) 2 Oneida Street, Rye Brook - NY: Employees were exposed to fall hazards of approximately 30 feet while using an extension ladder to access a roof that was not extended at least 3 feet above the surface in which they were accessing, on or about January 4th, 2023. |
|
|