Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-03-25
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2022-09-08
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2022-05-04 |
Current Penalty |
6164.0 |
Initial Penalty |
6164.0 |
Final Order |
2022-05-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish an energy control program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated and rendered inoperable. a) On or about 03/25/2022; throughout establishment, an energy control program was not established that consists of specific energy control procedures, authorized employee training and periodic inspections to ensure employees perform energy control procedures before servicing or doing maintenance such as but not limited to, changing dies or doing inspections on mechanical power presses such as, but not limited to: US 75 press, Russell JJ press NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2022-05-04 |
Abatement Due Date |
2022-05-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-05-31 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 03/25/2022, throughout establishment, employer did not conduct periodic inspections of the Lockout/Tagout procedures for employees that perform servicing/maintenance activities such as, but not limited to: changing dies or performing inspections on power presses. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C07 IV |
Issuance Date |
2022-05-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-05-31 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iv):The employer did not certify that employee training had been accomplished and kept up to date: a) On or about 03/25/2022; throughout establishment, when employees had lockout/Tagout authorized employee training, the employer did not certify that employee training had been accomplished and kept up to date. NO ABATEMENT CERTIFICATION REQUIRED |
|
|