Name: | GB ROYAL CONSTRUCTION INC |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 10 Feb 2021 (4 years ago) |
Entity Number: | 5938516 |
ZIP code: | 11783 |
County: | New York |
Place of Formation: | New York |
Address: | 3779 VERLEYE STREET, SEAFORD, NY, United States, 11783 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
SANDRA L GABARRETTE AMADOR | DOS Process Agent | 3779 VERLEYE STREET, SEAFORD, NY, United States, 11783 |
Name | Role | Address |
---|---|---|
SANDRA L. GABARRETTE AMADOR | Chief Executive Officer | 3779 VERLEYE STREET, SEAFORD, NY, United States, 11783 |
Start date | End date | Type | Value |
---|---|---|---|
2021-02-10 | 2024-11-04 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2021-02-10 | 2024-11-04 | Address | 3779 VERLEYE STREET, SEAFORD, NY, 11783, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
241104003835 | 2024-11-04 | BIENNIAL STATEMENT | 2024-11-04 |
210210010185 | 2021-02-10 | CERTIFICATE OF INCORPORATION | 2021-02-10 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346855331 | 0214700 | 2023-07-25 | 370 CHURCH STREET, WOODMERE, NY, 11598 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1601290 |
Safety | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2022-06-10 |
Emphasis | L: FALL, P: FALL |
Related Activity
Type | Inspection |
Activity Nr | 1601292 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260025 A |
Issuance Date | 2022-12-06 |
Abatement Due Date | 2022-12-12 |
Current Penalty | 2486.0 |
Initial Penalty | 2486.0 |
Final Order | 2023-01-05 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a) Worksite, residential structure - On or about 6/10/2022, employees were walking and working on and around accumulations of construction debris throughout the worksite. b) Worksite, residential structure - On or about 6/17/2022, employees were walking and working on and around accumulations of construction debris throughout the worksite. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2022-12-06 |
Abatement Due Date | 2022-12-12 |
Current Penalty | 3108.0 |
Initial Penalty | 3108.0 |
Final Order | 2023-01-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) Worksite, residential structure - On or about 6/10/2022, employees were exposed to being struck by lumber while working directly below over head framing. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2022-12-06 |
Abatement Due Date | 2022-12-12 |
Current Penalty | 3108.0 |
Initial Penalty | 3108.0 |
Final Order | 2023-01-05 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a) Worksite, residential structure - On or about 6/10/2022, employee was exposed to falling approximately 25 feet while installing roof rafters on a residential home. b) Worksite, residential structure - On or about 6/17/2022, employee was exposed to falling approximately 25 feet while installing asphalt shingles on a residential home. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |