Name: | CLEMENTE'S CONTRACTING INC |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 01 Apr 2021 (4 years ago) |
Entity Number: | 5978959 |
ZIP code: | 12589 |
County: | Orange |
Place of Formation: | New York |
Address: | 2056 ROUTE 300 #2, WALLKILL, NY, United States, 12589 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
CLEMENTE'S CONTRACTING INC | DOS Process Agent | 2056 ROUTE 300 #2, WALLKILL, NY, United States, 12589 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
210401010435 | 2021-04-01 | CERTIFICATE OF INCORPORATION | 2021-04-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347231128 | 0216000 | 2023-08-01 | 9 COX AVENUE, YONKERS, NY, 10704 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2024-01-29 |
Current Penalty | 5531.0 |
Initial Penalty | 5531.0 |
Final Order | 2024-03-14 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. A) 9 Cox Avenue, Yonkers - NY: Employees were exposed to eye/face injuries while using pneumatic nail guns during roofing/siding work. The employees were not protected by eye/face protection, on or about, August 1st, 2023. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2024-01-29 |
Current Penalty | 5531.0 |
Initial Penalty | 5531.0 |
Final Order | 2024-03-14 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. A) 9 Cox Avenue, Yonkers - NY: An employee was exposed to fall hazards of approximately 15 feet while working on a ladder jack scaffold with no fall protective devices, on or about, August 1st, 2023. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-01-29 |
Current Penalty | 6452.0 |
Initial Penalty | 6452.0 |
Final Order | 2024-03-14 |
Nr Instances | 1 |
Nr Exposed | 6 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest systems. A) 9 Cox Avenue, Yonkers - NY : Employees were exposed to fall hazards of approximately 17 feet while engaged in roofing work on a residential structure without a means of fall protection in place, on or about, August 1st, 2023. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2024-01-29 |
Current Penalty | 3687.0 |
Initial Penalty | 3687.0 |
Final Order | 2024-03-14 |
Nr Instances | 1 |
Nr Exposed | 6 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access: A) 9 Cox Avenue, Yonkers - NY: Employees were exposed to fall hazards of approximately 16 feet while using an extension ladder to access a roof. The extension ladder that was used was not extended at least 3 feet above the surface in which they were accessing, on or about, August 1st, 2023. |
Date of last update: 22 Mar 2025
Sources: New York Secretary of State