Search icon

OCHOA HOME RENOVATIONS INC

Company Details

Name: OCHOA HOME RENOVATIONS INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 28 Apr 2021 (4 years ago)
Entity Number: 6000645
ZIP code: 12206
County: New York
Place of Formation: New York
Address: 55 SYCAMORE ST, ALBANY, NY, United States, 12206

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
DARWIN OSWALDO OCHOA DOS Process Agent 55 SYCAMORE ST, ALBANY, NY, United States, 12206

History

Start date End date Type Value
2021-04-28 2023-10-17 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
210428020126 2021-04-28 CERTIFICATE OF INCORPORATION 2021-04-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347090896 0213100 2023-11-08 663 COUNTY ROUTE 7, EAST SCHODACK, NY, 12063
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2023-11-08
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2100929
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2023-12-07
Abatement Due Date 2023-12-13
Current Penalty 2009.0
Initial Penalty 2009.0
Final Order 2024-02-02
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) Worksite, Barn roof: On or about November 8, 2023, a roofer was utilizing a pneumatic nail gun on a barn roof, approximately 15 feet above the ground, and was not wearing eye or face protection. b) Worksite, Residential Home, Second Floor Roof: On or about November 8, 2023, two roofers were utilizing a pneumatic nail gun on the second-floor roof, approximately 25 feet above the ground, and were not wearing eye or face protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2023-12-07
Abatement Due Date 2023-12-19
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2024-02-02
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. a) Worksite, Barn roof: On or about November 8, 2023, an employee was conducting roofing activities on a barn roof, approximately 15 feet above the ground and was not protected from falls.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-12-07
Abatement Due Date 2023-12-19
Current Penalty 4688.0
Initial Penalty 4688.0
Final Order 2024-02-02
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) Worksite, Residential home, porch roof: On or about November 8, 2023, an employee was conducting roofing activities on a porch roof of a residential home, approximately 10 feet above the ground, and was not protected from falls. b) Worksite, Residential home, 2nd floor roof: On or about November 8, 2023, employees were conducting roofing activities on a second-floor roof of a residential home, approximately 25 feet above the ground, and were not protected from falls.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-12-07
Abatement Due Date 2023-12-19
Current Penalty 4018.0
Initial Penalty 4018.0
Final Order 2024-02-02
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. a) Worksite, porch roof: On or about November 8, 2023, an employee was using an extension ladder to access a porch roof, approximately 10 feet above the ground. The side rails of the ladder extended approximately 12 inches above the landing zone.

Date of last update: 22 Mar 2025