Search icon

BELLA VITA INDUSTRIES INC.

Company Details

Name: BELLA VITA INDUSTRIES INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 03 May 2021 (4 years ago)
Entity Number: 6003336
ZIP code: 11692
County: Queens
Place of Formation: New York
Address: 71-10 BEACH CHANNEL DR., FAR ROCKAWAY, NY, United States, 11692

Shares Details

Shares issued 100

Share Par Value 0.001

Type PAR VALUE

DOS Process Agent

Name Role Address
BELLA VITA INDUSTRIES INC. DOS Process Agent 71-10 BEACH CHANNEL DR., FAR ROCKAWAY, NY, United States, 11692

Agent

Name Role Address
UNITED STATES CORPORATION AGENTS, INC. Agent 7014 13TH AVENUE, SUITE 202, BROOKLYN, NY, 11228

History

Start date End date Type Value
2021-05-03 2023-07-01 Shares Share type: PAR VALUE, Number of shares: 100, Par value: 0.001

Filings

Filing Number Date Filed Type Effective Date
210503010001 2021-05-03 CERTIFICATE OF INCORPORATION 2021-05-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345956189 0215000 2022-05-13 2062 & 2064 ROYCE STREET, BROOKLYN, NY, 11234
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2022-05-13
Case Closed 2022-05-20

Related Activity

Type Inspection
Activity Nr 1558188
Safety Yes
345581888 0215000 2021-10-15 2062 & 2064 ROYCE ST, BROOKLYN, NY, 11234
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-10-15
Emphasis L: LOCALTARG, P: LOCALTARG

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2022-03-23
Current Penalty 4972.0
Initial Penalty 4972.0
Final Order 2022-04-19
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. Location: 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) The employer did not ensure that equipment was used in accordance with the instructions on the listing and labeling; employees used an extension cord to energize a miter saw and it was not listed for use in a construction setting.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2022-03-23
Current Penalty 5801.0
Initial Penalty 5801.0
Final Order 2022-04-19
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Location: 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) Employee worked from a scaffold platform that was not fully planked. The working platform had two planks and the space between the planks was more than two feet.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2022-03-23
Current Penalty 5801.0
Initial Penalty 5801.0
Final Order 2022-04-19
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platform(s) more than 2 feet above or below a point of access. Cross braces were used as a means of access.: Location: 2064 Royce Street, Brooklyn, NY; front of building On or about 10/15/2021 a) A 3-tier high supported scaffold had no safe means of access. An employee climbed the scaffold frames and cross braces to access the working platform.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2022-03-23
Current Penalty 5801.0
Initial Penalty 5801.0
Final Order 2022-04-19
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). Note: For voltage less than 300 volts the minimum distance is 3 feet. Location: 2062 Royce Street, Brooklyn, NY On or about 10/15/2021 a) A 3-frame high supported scaffold was erected less than 3 feet away from the power line. The service voltage of the power line was 110 volts.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2022-03-23
Abatement Due Date 2022-04-04
Current Penalty 5801.0
Initial Penalty 5801.0
Final Order 2022-04-19
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Location: 2062 & 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) The employer did not ensure the supported scaffold in use was erected under the supervision and direction of a competent person qualified in scaffold erection. The scaffold was not equipped with guardrails, had no safe means of access and working platforms were not fully planked.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 G04 I
Issuance Date 2022-03-23
Current Penalty 5801.0
Initial Penalty 5801.0
Final Order 2022-04-19
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews. Location: 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) Employee worked from 3 frame high supported scaffold and the scaffold was not equipped with guardrails.

Date of last update: 22 Mar 2025

Sources: New York Secretary of State