Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-10-15
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2022-03-23 |
Current Penalty |
4972.0 |
Initial Penalty |
4972.0 |
Final Order |
2022-04-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. Location: 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) The employer did not ensure that equipment was used in accordance with the instructions on the listing and labeling; employees used an extension cord to energize a miter saw and it was not listed for use in a construction setting. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 I |
Issuance Date |
2022-03-23 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-04-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(i):Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Location: 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) Employee worked from a scaffold platform that was not fully planked. The working platform had two planks and the space between the planks was more than two feet. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2022-03-23 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-04-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platform(s) more than 2 feet above or below a point of access. Cross braces were used as a means of access.: Location: 2064 Royce Street, Brooklyn, NY; front of building On or about 10/15/2021 a) A 3-tier high supported scaffold had no safe means of access. An employee climbed the scaffold frames and cross braces to access the working platform. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 F06 |
Issuance Date |
2022-03-23 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-04-19 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). Note: For voltage less than 300 volts the minimum distance is 3 feet. Location: 2062 Royce Street, Brooklyn, NY On or about 10/15/2021 a) A 3-frame high supported scaffold was erected less than 3 feet away from the power line. The service voltage of the power line was 110 volts. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2022-03-23 |
Abatement Due Date |
2022-04-04 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-04-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Location: 2062 & 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) The employer did not ensure the supported scaffold in use was erected under the supervision and direction of a competent person qualified in scaffold erection. The scaffold was not equipped with guardrails, had no safe means of access and working platforms were not fully planked. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260451 G04 I |
Issuance Date |
2022-03-23 |
Current Penalty |
5801.0 |
Initial Penalty |
5801.0 |
Final Order |
2022-04-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews. Location: 2064 Royce Street, Brooklyn, NY On or about 10/15/2021 a) Employee worked from 3 frame high supported scaffold and the scaffold was not equipped with guardrails. |
|
|