346963747
|
0216000
|
2023-09-05
|
1401 INWOOD AVE, BRONX, NY, 10452
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-09-11
|
Emphasis |
N: FALL
|
Related Activity
Type |
Complaint |
Activity Nr |
2074534 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1697683 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1695905 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1694683 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1696357 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 F14 |
Issuance Date |
2023-12-06 |
Current Penalty |
3000.0 |
Initial Penalty |
4688.0 |
Final Order |
2023-12-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: On or about September 5th, 2023 Location: 1401 Inwood Ave, Bronx, NY 10452 a) Employee working on a scissor lift standing on the rails while conducting work. |
|
|
346308158
|
0216000
|
2022-10-17
|
600 NORTH AVE., NEW ROCHELLE, NY, 10801
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-03-15
|
Case Closed |
2024-04-17
|
Related Activity
Type |
Complaint |
Activity Nr |
1962045 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2023-03-22 |
Current Penalty |
0.0 |
Initial Penalty |
8595.0 |
Contest Date |
2023-04-17 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees were working from a tubular welded frame scaffold, while engaged in masonry work. The working levels of the scaffold were not fully decked. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 II |
Issuance Date |
2023-03-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2023-04-17 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) An employee was working from a tubular welded frame scaffold, while engaged in masonry work. The working level was supported by a piece of metal that was not designed as a platform support. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2023-03-22 |
Current Penalty |
0.0 |
Initial Penalty |
8595.0 |
Contest Date |
2023-04-17 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
5 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees were working from a tubular welded frame scaffold, while engaged in masonry work. The employees were not provided with adequate access. Employees were climbing the walk through frames, using crossbraces and jumping from one level to another. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2023-03-22 |
Current Penalty |
0.0 |
Initial Penalty |
8595.0 |
Contest Date |
2023-04-17 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees, engaged in masonry work, were walking on/working from a tubular welded frame scaffold. A daily inspection of the scaffold was not done by a competent person. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2023-03-22 |
Current Penalty |
0.0 |
Initial Penalty |
12031.0 |
Contest Date |
2023-04-17 |
Final Order |
2023-10-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees, engaged in masonry work from a tubular welded frame scaffold, were not provided with adequate fall protection. The employees were exposed to a fall of up to 40 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
|
346130719
|
0215000
|
2022-08-08
|
886 BROADWAY, BROOKLYN, NY, 11206
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-08-08
|
Emphasis |
P: LOCALTARG, L: LOCALTARG
|
Case Closed |
2022-12-30
|
Related Activity
Type |
Inspection |
Activity Nr |
1613279 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613274 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613295 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1613257 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1608886 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613296 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1613287 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613288 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2022-11-10 |
Current Penalty |
2000.0 |
Initial Penalty |
3108.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous. a) 4th floor: On or about August 8, 2022: Workers were cutting bricks with a a masonry, which was energized by plugging in an extension cord and the cord was missing a ground pin. |
|
|
346132954
|
0215000
|
2022-08-08
|
886 BROADWAY, BROOKLYN, NY, 11206
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2022-08-08
|
Emphasis |
N: HEATNEP, P: HEATNEP
|
Case Closed |
2022-10-13
|
Related Activity
Type |
Inspection |
Activity Nr |
1613288 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1613296 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1613287 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613071 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1608886 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613257 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613279 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1613274 |
Safety |
Yes |
|
|