Search icon

Y & C MASONRY LLC

Company Details

Name: Y & C MASONRY LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 07 May 2021 (4 years ago)
Entity Number: 6008149
ZIP code: 11369
County: Queens
Place of Formation: New York
Address: 31-26 105TH STREET, EAST ELMHURST, NY, United States, 11369

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 31-26 105TH STREET, EAST ELMHURST, NY, United States, 11369

Filings

Filing Number Date Filed Type Effective Date
210507010178 2021-05-07 ARTICLES OF ORGANIZATION 2021-05-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346963747 0216000 2023-09-05 1401 INWOOD AVE, BRONX, NY, 10452
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2023-09-11
Emphasis N: FALL

Related Activity

Type Complaint
Activity Nr 2074534
Safety Yes
Type Inspection
Activity Nr 1697683
Safety Yes
Type Inspection
Activity Nr 1695905
Safety Yes
Type Inspection
Activity Nr 1694683
Safety Yes
Type Inspection
Activity Nr 1696357
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 F14
Issuance Date 2023-12-06
Current Penalty 3000.0
Initial Penalty 4688.0
Final Order 2023-12-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: On or about September 5th, 2023 Location: 1401 Inwood Ave, Bronx, NY 10452 a) Employee working on a scissor lift standing on the rails while conducting work.
346308158 0216000 2022-10-17 600 NORTH AVE., NEW ROCHELLE, NY, 10801
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2023-03-15
Case Closed 2024-04-17

Related Activity

Type Complaint
Activity Nr 1962045
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2023-03-22
Current Penalty 0.0
Initial Penalty 8595.0
Contest Date 2023-04-17
Final Order 2023-10-02
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees were working from a tubular welded frame scaffold, while engaged in masonry work. The working levels of the scaffold were not fully decked. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2023-03-22
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-04-17
Final Order 2023-10-02
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) An employee was working from a tubular welded frame scaffold, while engaged in masonry work. The working level was supported by a piece of metal that was not designed as a platform support. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2023-03-22
Current Penalty 0.0
Initial Penalty 8595.0
Contest Date 2023-04-17
Final Order 2023-10-02
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees were working from a tubular welded frame scaffold, while engaged in masonry work. The employees were not provided with adequate access. Employees were climbing the walk through frames, using crossbraces and jumping from one level to another. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2023-03-22
Current Penalty 0.0
Initial Penalty 8595.0
Contest Date 2023-04-17
Final Order 2023-10-02
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees, engaged in masonry work, were walking on/working from a tubular welded frame scaffold. A daily inspection of the scaffold was not done by a competent person. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2023-03-22
Current Penalty 0.0
Initial Penalty 12031.0
Contest Date 2023-04-17
Final Order 2023-10-02
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: location: Scaffold set up beside the front exterior of building on or about: 10/12/22 a) Employees, engaged in masonry work from a tubular welded frame scaffold, were not provided with adequate fall protection. The employees were exposed to a fall of up to 40 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
346130719 0215000 2022-08-08 886 BROADWAY, BROOKLYN, NY, 11206
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2022-08-08
Emphasis P: LOCALTARG, L: LOCALTARG
Case Closed 2022-12-30

Related Activity

Type Inspection
Activity Nr 1613279
Safety Yes
Type Inspection
Activity Nr 1613274
Safety Yes
Type Inspection
Activity Nr 1613295
Health Yes
Type Inspection
Activity Nr 1613257
Safety Yes
Type Inspection
Activity Nr 1608886
Safety Yes
Type Inspection
Activity Nr 1613296
Health Yes
Type Inspection
Activity Nr 1613287
Safety Yes
Type Inspection
Activity Nr 1613288
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2022-11-10
Current Penalty 2000.0
Initial Penalty 3108.0
Final Order 2022-11-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous. a) 4th floor: On or about August 8, 2022: Workers were cutting bricks with a a masonry, which was energized by plugging in an extension cord and the cord was missing a ground pin.
346132954 0215000 2022-08-08 886 BROADWAY, BROOKLYN, NY, 11206
Inspection Type Prog Related
Scope Partial
Safety/Health Health
Close Conference 2022-08-08
Emphasis N: HEATNEP, P: HEATNEP
Case Closed 2022-10-13

Related Activity

Type Inspection
Activity Nr 1613288
Health Yes
Type Inspection
Activity Nr 1613296
Health Yes
Type Inspection
Activity Nr 1613287
Safety Yes
Type Inspection
Activity Nr 1613071
Safety Yes
Type Inspection
Activity Nr 1608886
Safety Yes
Type Inspection
Activity Nr 1613257
Safety Yes
Type Inspection
Activity Nr 1613279
Safety Yes
Type Inspection
Activity Nr 1613274
Safety Yes

Date of last update: 22 Mar 2025