Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2024-05-09
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2024-09-19 |
Current Penalty |
4147.8 |
Initial Penalty |
6913.0 |
Final Order |
2024-10-14 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) 1111 Corporate Drive, Farmington, NY 14425, on or about 5/9/2024; Employee are required to lockout/tagout bag and pouch making equipment during startup/troubleshooting/and run off tasks and the employer did not develop equipment specific energy controls procedures on the bag and pouch making equipment. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2024-09-19 |
Abatement Due Date |
2024-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-10-14 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) 1111 Corporate Drive, Farmington, NY 14425, on or about 5/9/2024; The employer did not conduct periodic inspections of the energy controls procedures on the bag and pouch making equipment. Abatement certification is required. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-09-19 |
Current Penalty |
4701.0 |
Initial Penalty |
7835.0 |
Final Order |
2024-10-14 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Machine Shop, 1111 Corporate Drive, Farmington, NY 14425, on or about 5/9/2024: TRAK-TRM, Serial Number 95-640, Manual Mill was not provided with chuck and tool guard. b) Machine Shop, 1111 Corporate Drive, Farmington, NY 14425, on or about 5/9/2024: The COMET, Serial Number 1020, Manual Mill was not provided with chuck and tool guard. c) Machine Shop, 1111 Corporate Drive, Farmington, NY 14425, on or about 5/9/2024: The Bridgeport, Serial Number HJ323454, Manual Mill was not provided with chuck and tool guard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2024-09-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-10-14 |
Nr Instances |
1 |
Nr Exposed |
22 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) 1111 Corporate Drive, Farmington, NY 14425, on or about 5/9/2024; The employer did not have a certified written workplace hazard assessment for personal protective equipment required in the facility. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100147 C07 IV |
Issuance Date |
2024-09-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-10-14 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iv): The employer did not keep the accomplished certified employee training to date: a) 1111 Corporate Drive, Farmington, NY 14425, on or about 5/9/2024; The employer did not certify that authorized employees were trained, to include each employee's name and dates of training. |
|
|