Search icon

NAMICELA HOME SOLUTIONS INC

Company Details

Name: NAMICELA HOME SOLUTIONS INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 09 Jun 2021 (4 years ago)
Entity Number: 6032198
ZIP code: 13211
County: Onondaga
Place of Formation: New York
Address: 311 w molloy rd, SYRACUSE, NY, United States, 13211

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
the corporation DOS Process Agent 311 w molloy rd, SYRACUSE, NY, United States, 13211

History

Start date End date Type Value
2021-06-09 2022-11-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-06-09 2022-11-19 Address 6 CORWIN AVE, MIDDLETOWN, NY, 10940, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
221119000650 2022-11-18 CERTIFICATE OF CHANGE BY ENTITY 2022-11-18
210609010166 2021-06-09 CERTIFICATE OF INCORPORATION 2021-06-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347628836 0215800 2024-07-08 TIMBER BANKS, TALL TREE LANE LOT 327, BALDWINSVILLE, NY, 13027
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2024-07-08
Emphasis N: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-12-18
Current Penalty 3266.25
Initial Penalty 4355.0
Final Order 2025-01-15
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Timber Banks, Tall Tree Lane, Lot 327, Baldwinsville, NY 13027, on the roof, on or about 7/8/24: Employees installing roofing material without fall protection onto a two-story residential building, with a 10:12 pitch on the main roof and a 12:12 pitch on the gable sections, were exposed to fall hazards of 13 feet.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260502 E02
Issuance Date 2024-12-18
Current Penalty 3266.25
Initial Penalty 4355.0
Final Order 2025-01-15
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(e)(2): Positioning devices were not secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever was greater: a) Timber Banks, Tall Tree Lane, Lot 327, Baldwinsville, NY 13027, on the roof, on or about 7/8/24: Employees used positioning systems to install roofing on a two-story residential building, with a 10:12 and 12:12 pitch roof, where the anchorage could not support at least twice the potential impact load in a fall or 3,000 lbs. Employees were exposed to a fall of 13 feet .
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-12-18
Abatement Due Date 2025-02-06
Current Penalty 2333.25
Initial Penalty 3111.0
Final Order 2025-01-15
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 9 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Timber Banks, Tall Tree Lane, Lot 327, Baldwinsville, NY 13027, on the roof, on or about 7/8/24: Employees were not trained to recognize fall hazards and the procedures to follow to minimize fall hazards, when multiple errors were identified with the application of personal fall arrest systems and positioning systems on site. Abatement certification must be submitted for this item.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-12-18
Current Penalty 2333.25
Initial Penalty 3111.0
Final Order 2025-01-15
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Timber Banks, Tall Tree Lane, Lot 327, Baldwinsville, NY 13027, accessing the roof, on or about 7/8/24: Employees were using an articulating aluminum ladder to access and egress the roof where that ladder did not extend at least 3 feet above the upper landing.
346687247 0215800 2023-05-08 8436 SILVER SPRUCE CIRCLE, LIVERPOOL, NY, 13090
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-05-08
Emphasis L: FALL
Case Closed 2023-10-24

Related Activity

Type Complaint
Activity Nr 2028728
Safety Yes
Type Inspection
Activity Nr 1668630
Safety Yes

Date of last update: 05 Mar 2025

Sources: New York Secretary of State