Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-10-11
|
Emphasis |
N: FALL
|
Related Activity
Type |
Referral |
Activity Nr |
2091457 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1702708 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1702693 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B05 II |
Issuance Date |
2024-02-15 |
Abatement Due Date |
2024-02-26 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-04-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(5)(ii):The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were performing siding installation while working from a ladder jack scaffold. The scaffold platform extended approximately 5 feet past the support; on or about 10/11/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2024-02-15 |
Abatement Due Date |
2024-02-26 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-04-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platform(s) more than 2 feet above or below a point of access. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were not protected from falling to the ground approximately 16.5 feet while accessing a ladder jack scaffold using the scaffold support ladders; on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2024-02-15 |
Abatement Due Date |
2024-02-26 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-04-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were not protected from falling to the ground approximately 16.5 feet while performing siding installation from a ladder jack scaffold; on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260452 K04 |
Issuance Date |
2024-02-15 |
Abatement Due Date |
2024-02-26 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-04-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(k)(4): Ladders used to support ladder jacks shall be placed, fastened, or equipped with devices to prevent slipping. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were not protected from falling to the ground approximately 16.5 feet while performing siding installation from a ladder jack scaffold which was not placed, fastened, or equipped with devices to prevent slipping, on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2024-02-15 |
Abatement Due Date |
2024-02-26 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-04-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a):The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Worksite: 112 Harbor Road, Cold Spring Harbor, NY 11724 - The employees were performing siding installation from a ladder jack scaffold were not trained properly to recognize the hazards associated with the type of scaffold being used and to understand the procedure to control or minimize those hazards; on or about 10/11/23. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|