Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347516981 | 0215000 | 2024-05-29 | 625 FULTON STREET, BROOKLYN, NY, 11201 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1751471 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1751472 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1751469 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1632028 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1751470 |
Safety | Yes |
Inspection Type | Fat/Cat |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2022-11-02 |
Emphasis | L: FALL |
Related Activity
Type | Accident |
Activity Nr | 1964197 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 F07 |
Issuance Date | 2023-05-01 |
Abatement Due Date | 2023-05-11 |
Current Penalty | 7300.0 |
Initial Penalty | 10938.0 |
Contest Date | 2023-05-17 |
Final Order | 2023-11-13 |
Nr Instances | 1 |
Nr Exposed | 8 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Site: 625 Fulton Street Brooklyn, NY On or about 11/02/2022 a) Employees were erecting a sidewalk/bridge shed without the supervision and direction of a competent person. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2023-05-01 |
Abatement Due Date | 2023-05-11 |
Current Penalty | 4400.0 |
Initial Penalty | 7813.0 |
Contest Date | 2023-05-17 |
Final Order | 2023-11-13 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed. Site: 625 Fulton Street Brooklyn, NY On or about 11/02/2022 a) Employees accessed the sidewalk shed by using an A-frame ladder which was kept closed and leaned against the platform which was approximately 11 feet above the ground. |
Citation ID | 02001 |
Citaton Type | Willful |
Standard Cited | 19260451 G02 |
Issuance Date | 2023-05-01 |
Abatement Due Date | 2023-05-11 |
Current Penalty | 78300.0 |
Initial Penalty | 109381.0 |
Contest Date | 2023-05-17 |
Final Order | 2023-11-13 |
Nr Instances | 1 |
Nr Exposed | 8 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(2): The employer did not provide fall protection for employees erecting or dismantling supported scaffolds where the installation and use of such protection was feasible and did not create a greater hazard. Site: 625 Fulton Street Brooklyn, NY On or about 11/02/2022 a) The employer did not provide fall protection for employees erecting a sidewalk shed where the use of it was feasible and did not create a greater hazard. Employees were exposed to falls of approximately 20 feet. |