Search icon

GLEASON AVERY LLC

Company Details

Name: GLEASON AVERY LLC
Jurisdiction: New York
Legal type: FOREIGN LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 01 Oct 2021 (3 years ago)
Entity Number: 6294652
ZIP code: 14623
County: Monroe
Place of Formation: Delaware
Foreign Legal Name: GLEASON AVERY LLC
Address: 3540 WINTON PLACE, ROCHESTER, NY, United States, 14623

DOS Process Agent

Name Role Address
GLEASON AVERY LLC DOS Process Agent 3540 WINTON PLACE, ROCHESTER, NY, United States, 14623

History

Start date End date Type Value
2022-03-25 2023-10-04 Address 3540 WINTON PLACE, ROCHESTER, NY, 14623, USA (Type of address: Service of Process)
2021-10-04 2022-03-25 Address 3540 WINTON PLACE, ROCHESTER, DE, 19808, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
231004001224 2023-10-04 BIENNIAL STATEMENT 2023-10-01
220325000451 2022-03-24 CERTIFICATE OF PUBLICATION 2022-03-24
211004000090 2021-10-01 APPLICATION OF AUTHORITY 2021-10-01

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347674038 0215800 2024-08-08 45 AURELIUS AVENUE, AUBURN, NY, 13021
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2024-08-08
Emphasis N: AMPUTATE, P: AMPUTATE

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2024-11-27
Current Penalty 1382.5
Initial Penalty 2765.0
Final Order 2024-12-12
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): The employer did not provide employees with the information contained in Appendix D of the Respiratory Protection Standard ("Information for Employees Using Respirators When Not Required Under the Standard"), when the employer permitted employees to use respirators. a) Gleason Avery LLC, 45 Aurelius Avenue, Auburn, NY 13021, Spray Booth. On or about 8/08/2024, the employer did not provide employees with the information contained in Appendix D of the Respiratory Protection Standard ("Information for Employees Using Respirators When Not Required Under the Standard"), when the employer permitted employees to use 3M Half-Faced Respirators, Model 6200, with N95 filters, Model 2071.
Citation ID 01001B
Citaton Type Other
Standard Cited 19100134 C02 II
Issuance Date 2024-11-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-12-12
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(ii): The employer did not ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. a) Gleason Avery LLC, 45 Aurelius Avenue, Auburn, NY 13021, Spray Booth. On or about 8/08/2024, the employer did not ensure that any employee using a 3M Half-Faced Respirators, Model 6200, with N95 filters, Model 2071, voluntarily is medically able to use a respirator.
Citation ID 01002
Citaton Type Other
Standard Cited 19100178 L06
Issuance Date 2024-11-27
Current Penalty 1382.5
Initial Penalty 2765.0
Final Order 2024-12-12
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(6): The employer did not certify that each Powered Industrial Truck operator has been trained and evaluated as required by this paragraph (l): a) Gleason Avery LLC, 45 Aurelius Avenue, Auburn, NY 13021, Dock and Warehouse Areas. On or about 7/08/2024, the employer did not certify that the Powered Industrial Truck operator's performance on the Allis Chalmer, Model SR 40 CR H65XM, Serial Number DJD96743, had been evaluated.
344225909 0215800 2019-08-12 45 AURELIUS AVENUE, AUBURN, NY, 13021
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2019-08-12
Case Closed 2020-05-28

Related Activity

Type Complaint
Activity Nr 1485394
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2020-01-08
Abatement Due Date 2020-02-03
Current Penalty 2386.8
Initial Penalty 3978.0
Final Order 2020-01-24
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. In the production area, on or about 8/12/19: A relocatable power tap (RPT) was in use supplying power to electrical test strips which was not in accordance with the listing and labeling instructions. Abatement certification must be submitted for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2020-01-08
Abatement Due Date 2020-01-21
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-01-24
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. In the production area, on or about 8/12/19: Employees running motors were adjusting the voltage using a separate control. Strain relief was not provided where the power cord entered the voltage control housing. Abatement certification must be submitted for this item.
Citation ID 02001
Citaton Type Other
Standard Cited 19100305 B02 I
Issuance Date 2020-01-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-01-24
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a. In the production area at the motor run in stations, on or about 8/12/19: A junction box was not equipped with a cover approved for that purpose.
339841298 0215800 2014-07-09 46 AURELIUS AVENUE, AUBURN, NY, 13021
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2014-07-09
Case Closed 2014-07-10

Related Activity

Type Inspection
Activity Nr 944302
Safety Yes
339443020 0215800 2013-10-24 45 AURELIUS AVENUE, AUBURN, NY, 13021
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2013-10-24
Case Closed 2014-07-10

Related Activity

Type Complaint
Activity Nr 856635
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100107 B09
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 2800.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a) Spray Booth Area, on or about 10/24/2013: Minimum clearance was not kept on the sides of the spray booth, employee was spraying flammable paint.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100107 C02
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(c)(2): 29 CFR 1910.107(c)(2): Open flame or spark producing equipment was within a spraying area and/or within 20 feet thereof, was not separated by a partition: a) Spray Booth Area, on or about 10/24/2013: Employees were using Bench Press and Drill Press capable of producing sparks in the Spray Booth area.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100107 C06
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 3
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.107(c)(6): Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spray area, and not separated therefrom by partitions, produced sparks under normal operating conditions and did not otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations: a) Spray Booth Area, on or about 10/24/2013: Duplex receptacle box not adequate for the location. b) Spray Booth Area, on or about 10/24/2013: Exhaust fan motor not adequate for the location. c) Spray Booth Area, on or about 10/24/2013: Florescent Lamps not adequate for the location.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100132 D01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 1400.0
Initial Penalty 2800.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: a) Throughout the Facility, on or about 10/24/2013: The employer had not performed a hazard assessment to protect employees from hazards that can be prevented by the use of personal protective equipment.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Sub Assembly Area, on or about 10/24/2013: Employee was exposed to flying particles when boring metal without adequate eye protection. b) Sub Assembly Area, on or about 10/24/2013: Employee was exposed to flying particles when cutting wire leads without adequate eye protection. c) Sub Assembly Area, on or about 10/24/2013: Employee was exposed to injurious light radiation when welding without adequate eye protection. d) Warehouse Area, on or about 10/24/2013: Employee was exposed to corrosives when adding water to batteries without adequate eye protection.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100136 A
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.136(a): The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet are exposed to electrical hazards: a) Warehouse Area, on or about 10/24/2013: Employee was carrying wire spools without safety shoes, exposing employee to a struck by hazard.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 1400.0
Initial Penalty 2800.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) At the Facility, on or about 10/24/2013: The employer had not developed a respiratory protection program, employee was mixing and spraying paint.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. Note: The employer may discontinue an employee medical evaluations when the employee is no longer required to use a respirator. a) At the Facility, on or about 10/24/2013: The employer had not provided medical evaluation to employees, employee was mixing and spraying paint.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19100134 K01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii): a) At the Facility, on or about 10/24/2013: Employee was spraying and mixing paint with a respirator not adequate for the purpose.
Citation ID 01004
Citaton Type Other
Standard Cited 19100178 L04 I
Issuance Date 2014-01-23
Current Penalty 0.0
Initial Penalty 2100.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(4)(i): 1910.178(l)(4)(i): The powered industrial truck operators (PITs) were not trained and evaluted once in three years. a) Warehouse Area, on or about 10/24/2013: The power industrial truck operator has not been evaluated in the last three years.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 1400.0
Initial Penalty 2800.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 10
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Sub Assembly Area, on or about 10/24/2013: Rockwell Drill Press was not provided with a guard over the rotating chuck. b) Sub Assembly Area, on or about 10/24/2013: Rivett Lathe and Grinder was not provided with a guard over the rotating chuck. c) Sub Assembly Area, on or about 10/24/2013: Le Blond lathe was not provided with a guard over the rotating chuck. d) Sub Assembly Area, on or about 10/24/2013: Two Delta Milwaukee Drill Press were not provided with a guard over the rotating chuck. e) Sub Assembly Area, on or about 10/24/2013: Kopis Machine was not provided with a guard to protect the operator from reaching the point of operation. f) Assembly Area, on or about 10/24/2013: Dayton Bench Drill was not provided with a guard over the rotating chuck. g) Gear Department, on or about 10/24/2013: Three Hardinge Lathe were not provided with a guard over the rotating chuck. h) Gear Department, on or about 10/24/2013: Two Delta Milwaukee Drill Press were not provided with a guard over the rotating chuck. i) Gear Department, on or about 10/24/2013: Six Barber Coleman Screw Machine were not provided with a guard to prevent operators from ingoing nip points. j) Gear Department, on or about 10/24/2013: South Bend Milling Machine was not provided with a guard over the rotating chuck.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Sub Assembly Area, on or about 10/24/2013: Punch Press Machine had an unguarded belt and pulley belt drive. b) Assembly Area, on or about 10/24/2013: Dayton Bench Drill had an unguarded belt and pulley belt drive.
Citation ID 01005C
Citaton Type Serious
Standard Cited 19100219 E01 I
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a) Assembly Area, on or about 10/24/2013: Dayton Bench Drill had an unguarded belt drive.
Citation ID 01005D
Citaton Type Serious
Standard Cited 19100219 E03 I
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Sub Assembly Area, on or about 10/24/2013: Punch Press Machine had an unguarded belt drive.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100304 G05
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 1050.0
Initial Penalty 2100.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Assembly Area, on or about 10/24/2013: Metal fan cord plug ground conductor missing was missing not maintaining a continuous path to ground.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 1400.0
Initial Penalty 2800.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 30
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Throughout the Facility, on or about 10/24/2013: The employer did not developed a written hazard communication program.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2014-01-23
Abatement Due Date 2014-03-12
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2014-02-13
Final Order 2014-06-09
Nr Instances 1
Nr Exposed 30
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Throughout the Facility, on or about 10/24/2013: The employer had not trained his employees on hazardous chemicals.

Date of last update: 04 Mar 2025