Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-03-08
|
Emphasis |
N: FALL
|
Related Activity
Type |
Complaint |
Activity Nr |
2139700 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1733578 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2024-04-17 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) On or about March 8, 2024, at the worksite 2512 Burnet Ave, Syracuse, NY 13206: Employees engaged in commercial roofing activities were not utilizing any fall protection system. Employees were exposed to fall hazards of 15 feet. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2024-04-17 |
Abatement Due Date |
2024-05-13 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about February 27, 2024, at the worksite 2546 South Avenue, Syracuse, NY 13207: when employees were exposed to fall hazards while engaged in residential roofing, the employer did not provide training in regards to the recognition and avoidance of fall hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2024-04-17 |
Abatement Due Date |
2024-05-13 |
Current Penalty |
2074.0 |
Initial Penalty |
2074.0 |
Final Order |
2024-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired: a) On or about March 8, 2024, at the worksite 2512 Burnet Ave, Syracuse, NY 13206: Employees used a portable ladder with a broken rung to access a 15 foot tall roof. |
|
|