Name: | ELI SEAMLESS GUTTERS INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 19 Jan 2022 (3 years ago) |
Entity Number: | 6379544 |
ZIP code: | 11901 |
County: | Suffolk |
Place of Formation: | New York |
Address: | 1233 West Main ST, Riverhead, NY, United States, 11901 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
WILVER CRUZ | DOS Process Agent | 1233 West Main ST, Riverhead, NY, United States, 11901 |
Name | Role | Address |
---|---|---|
WILVER ELISEO CRUZ GALDAMEZ | Chief Executive Officer | 1233 WEST MAIN ST, RIVERHEAD, NY, United States, 11901 |
Start date | End date | Type | Value |
---|---|---|---|
2022-06-24 | 2024-01-31 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2022-01-19 | 2022-06-24 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
240131004088 | 2024-01-31 | BIENNIAL STATEMENT | 2024-01-31 |
220119003608 | 2022-01-19 | CERTIFICATE OF INCORPORATION | 2022-01-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347202657 | 0214700 | 2024-01-09 | 99 MECOX POINT RD., BRIDGEHAMPTON, NY, 11932 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2024-07-02 |
Abatement Due Date | 2024-07-15 |
Current Penalty | 2060.0 |
Initial Penalty | 3457.0 |
Final Order | 2024-10-31 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite- 99 Mecox Point Lane, Bridgehampton, NY- Two employees were working on the third level of a scaffold preparing to install exterior window flashing on a residential home. The scaffold level they were working on had three planks and two planks were missing; on or about 1/8/24. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2024-07-02 |
Current Penalty | 2060.0 |
Initial Penalty | 3457.0 |
Final Order | 2024-10-31 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) Worksite, 99 Mecox Point Lane, Bridgehampton, NY- Two employees were working on the third level of a scaffold preparing to install exterior window flashing on a residential home. One employee was observed climbing the frame and crossbracing of the scaffold to descend from the 18' level; on or about 1/8/24. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2024-07-02 |
Abatement Due Date | 2024-07-09 |
Current Penalty | 2060.0 |
Initial Penalty | 3457.0 |
Final Order | 2024-10-31 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) Worksite- 99 Point Mecox Lane, Bridgehampton, NY- Two employees were working at the third level of a scaffold installing exterior window flashing on a residential construction. The employees were not protected from falls by use of guardrails or personal fall arrest systems; on or about 1/8/24. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4046115 | Intrastate Non-Hazmat | 2024-01-10 | 5000 | 2023 | 1 | 1 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 04 Mar 2025
Sources: New York Secretary of State