Name: | J. GORDON CONTRACTING LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 09 Feb 2022 (3 years ago) |
Entity Number: | 6399561 |
ZIP code: | 13116 |
County: | Onondaga |
Place of Formation: | New York |
Address: | 501 Edgerton St, Apt C3, Minoa, NY, United States, 13116 |
Name | Role | Address |
---|---|---|
THE LIMITED LIABILITY COMPANY | DOS Process Agent | 501 Edgerton St, Apt C3, Minoa, NY, United States, 13116 |
Name | Role | Address |
---|---|---|
UNITED STATES CORPORATION AGENTS, INC. | Agent | 7014 13TH AVENUE, SUITE 202, BROOKLYN, NY, 11228 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
220209002019 | 2022-02-09 | ARTICLES OF ORGANIZATION | 2022-02-09 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346420722 | 0215800 | 2023-01-06 | 302 BRYANT STREET, SYRACUSE, NY, 13204 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260451 B05 II |
Issuance Date | 2023-05-22 |
Abatement Due Date | 2023-06-16 |
Current Penalty | 2812.8 |
Initial Penalty | 4688.0 |
Final Order | 2023-07-31 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: a) 302 Bryant Street, Syracuse, NY 13204: On or about January 6, 2023, employees worked on a platform approximately 15 feet in length with the ends of the platform extended approximately 4 feet over its support without guardrails blocking employee access. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260416 A01 |
Issuance Date | 2023-05-22 |
Abatement Due Date | 2023-06-16 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-07-31 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work: a) 302 Bryant Street, Syracuse, NY 13204: On or about January 6, 2023, employees working on a scaffold were in close proximity to energized, unguarded, and ungrounded electric power circuits. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2023-05-22 |
Current Penalty | 2812.8 |
Initial Penalty | 4688.0 |
Final Order | 2023-07-31 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) 302 Bryant Street, Syracuse, NY 13204: On or about January 6, 2023, employer failed to ensure employees on scaffolds approximately 18 feet above a lower level were protected from falling. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2023-05-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-07-31 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) 302 Bryant Street, Syracuse, NY 13204: On or about January 6, 2023, employer failed to ensure employees working on the roof of a two-story house were protected from falling by the use of guardrails systems, safety net systems, or personal fall arrest systems. |
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4273939 | Intrastate Non-Hazmat | 2024-07-29 | - | - | 1 | 2 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 21 Mar 2025
Sources: New York Secretary of State