Search icon

ALVAREZ & SON HOME IMPROVEMENT INC.

Company Details

Name: ALVAREZ & SON HOME IMPROVEMENT INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 03 Mar 2022 (3 years ago)
Entity Number: 6420934
ZIP code: 10567
County: Westchester
Place of Formation: New York
Address: 3 LINCOLN PL, CORTLANDT MNR, NY, United States, 10567
Principal Address: 3 Lincoln Pl, Cortlandt Manor, NY, United States, 10567

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
ZOILA C ALVAREZ DOS Process Agent 3 LINCOLN PL, CORTLANDT MNR, NY, United States, 10567

Chief Executive Officer

Name Role Address
ZOILA C ALVAREZ Chief Executive Officer 3 LINCOLN PL, CORTLANDT MANOR, NY, United States, 10567

History

Start date End date Type Value
2022-03-03 2024-05-20 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
240520003506 2024-05-20 BIENNIAL STATEMENT 2024-05-20
220303002985 2022-03-03 CERTIFICATE OF INCORPORATION 2022-03-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347412140 0213100 2024-04-11 104-108 BENNINGTON DR., FISHKILL, NY, 12524
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2024-04-11
Emphasis N: FALL

Related Activity

Type Complaint
Activity Nr 2139721
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2024-10-07
Abatement Due Date 2024-10-11
Current Penalty 4839.0
Initial Penalty 4839.0
Final Order 2024-11-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) Building 104-108 - On or about April 11, 2024 and at times prior thereto, employees were working from a man made platform, without the use of fall protection, being lifted by a JCB Telescopic Forklift.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-10-07
Abatement Due Date 2024-10-11
Current Penalty 4839.0
Initial Penalty 4839.0
Final Order 2024-11-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) Building 104-108 - On or about April 11, 2024 and at times prior thereto, employees were framing the roof of a 2 story townhouse without the use of fall protection and exposed to falls of approximately 30 feet.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260602 C01 II
Issuance Date 2024-10-07
Abatement Due Date 2024-10-11
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-11-04
Nr Instances 2
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were made without the manufacturer's written approval: a) Building 104-108 - On or about April 11, 2024 and at times prior thereto, employees were working from a man made aerial platform, attached to a JCB 507-42 Telescopic Forklift, without the manufacturers approval. b) Building 104-108 - On or about April 11, 2024 and at times prior thereto, employees were working from a man made aerial platform, attached to a JCB 506C Telescopic Forklift, without the manufacturers approval.

Date of last update: 21 Mar 2025

Sources: New York Secretary of State