OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346175466 0213600 2022-08-25 2 WASHINGTON AVENUE, SILVER CREEK, NY, 14136
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-08-25
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2022-09-26
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2022-10-20
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 8/25/2022 at a roof project located at 2 Washington Avenue, Silver Creek, New York; employees were replacing the roof of a two story house. The roof had an 7 in 12 pitch and an eave height of approximately 22 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-09-26
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2022-10-20
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 8/25/2022 at a roof project located at 2 Washington Avenue, Silver Creek, New York; employees were replacing shingles on the roof of a one story building. Employees were accessing the roof with an extension ladder and the side rails of the ladder did not extend 3 feet above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2022-09-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-10-20
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 8/25/2022 at a roof project located at 2 Washington Avenue, Silver Creek, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED
345985865 0213600 2022-05-24 2 OAK STREET, BATAVIA, NY, 14020
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-05-24
Emphasis L: FALL, P: FALL
Case Closed 2024-04-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2022-07-29
Current Penalty 3108.0
Initial Penalty 3108.0
Final Order 2022-08-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 5/24/2022 at a roof project located at 2 Oak Street, Batavia, New York; employees were replacing the roof of a two story house. The roof had an 6 in 12 pitch and an eave height of approximately 18 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19260100 A
Issuance Date 2022-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-08-24
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 5/24/2022 at a roof project located at 2 Oak Street, Batavia, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED