Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-01-20
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2022-08-29
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100101 B |
Issuance Date |
2022-06-23 |
Abatement Due Date |
2022-07-18 |
Current Penalty |
5220.6 |
Initial Penalty |
7458.0 |
Final Order |
2022-08-16 |
Nr Instances |
3 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) At the Maintenance Shop, on or about 1/20/2022: Compressed Gas Cylinders which were not in use did not have valve protective caps. b) At the Maintenance Shop, on or about 1/20/2022: Compressed Gas Cylinders were not labeled with its contents. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100176 B |
Issuance Date |
2022-06-23 |
Current Penalty |
3915.8 |
Initial Penalty |
5594.0 |
Final Order |
2022-08-16 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) At the Warehouse's back exit aisle, on or about 1/20/2022: Pallets stacked greater than 14 feet were slanted creating a struck-by hazard should product collapse. b) At Freezer 2, Aisle 6, on or about 1/20/2022: Pallets and products were unsecured as the support bar was damaged, permitting pallet to slant and pallet pieces to fall. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2022-06-23 |
Abatement Due Date |
2022-07-18 |
Current Penalty |
5220.6 |
Initial Penalty |
7458.0 |
Final Order |
2022-08-16 |
Nr Instances |
2 |
Nr Exposed |
17 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: a) At Line 2, Conveyor-216, on or about 1/20/2022: Employees were exposed to nip points while retrieving sugar from bins as the conveyor belt was slacked and creating pinch point hazards should accidental contact occur. b) At Line 2, Conveyor-215, on or about 1/20/2022: Employees were exposed to nip points while retrieving cinnamon bins as the conveyor belt was slacked and thus creating pinch point hazards should accidental contact occur. c) At the Machine Shop, on or about 1/20/2022: Employees were exposed to contact with a rotating chuck when operating a Bridgeport Mill Drill, as it was unguarded. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2022-06-23 |
Abatement Due Date |
2022-07-18 |
Current Penalty |
5220.6 |
Initial Penalty |
7458.0 |
Final Order |
2022-08-16 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) At the Line 2 Mixing Area, on or about 1/20/2022: Electrical outlets for the water matt and IPM station designated to be used with covers in the closed position as to protect from dust particles entering electrical components were not utilized as designated in that they were kept in the open position, exposing the workers to electrical fire hazards. |
|
|