Name: | ALBANY FIRE EXTINGUISHER, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 21 Jul 2022 (3 years ago) |
Entity Number: | 6542294 |
ZIP code: | 12110 |
County: | Albany |
Place of Formation: | New York |
Address: | 36 Cambridge Way, Latham, NY, United States, 12110 |
Plan Name | Plan Year | EIN/PN | Received | Sponsor | Total number of participants | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ALBANY FIRE EXTINGUISHER, LLC 401(K) PS PLAN | 2023 | 883563855 | 2024-07-16 | ALBANY FIRE EXTINGUISHER, LLC | 19 | |||||||||||||||||||||||||||||
|
Role | Plan administrator |
Date | 2024-07-16 |
Name of individual signing | LINDSAY WILLIS |
Role | Employer/plan sponsor |
Date | 2024-07-16 |
Name of individual signing | LINDSAY WILLIS |
Name | Role | Address |
---|---|---|
THE LIMITED LIABILITY COMPANY | DOS Process Agent | 36 Cambridge Way, Latham, NY, United States, 12110 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
240827000297 | 2024-08-27 | BIENNIAL STATEMENT | 2024-08-27 |
220721002939 | 2022-07-21 | ARTICLES OF ORGANIZATION | 2022-07-21 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346872294 | 0213100 | 2023-07-31 | 215 WATERVLIET SHAKER ROAD, WATERVLIET, NY, 12189 | |||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 2060920 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100101 A |
Issuance Date | 2024-01-12 |
Abatement Due Date | 2024-01-25 |
Current Penalty | 6250.0 |
Initial Penalty | 6250.0 |
Contest Date | 2024-02-06 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.101(a): The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that can be determined by visual or other inspections conducted as prescribed in the Hazardous Materials Regulations (a) Establishment, Fire extinguisher shop - On or about July 28, 2023, an employee was recharging a 20 lbs Buckeye ABC Fire Extinguisher Model 20SHISA with nitrogen to remove its chemical agent, when the cylinder ruptured striking the employee. |
Date of last update: 21 Mar 2025
Sources: New York Secretary of State