Search icon

Y&L BEST REMODELING CORP.

Company Details

Name: Y&L BEST REMODELING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 28 Jul 2022 (3 years ago)
Entity Number: 6547513
ZIP code: 12207
County: Albany
Place of Formation: New York
Address: 418 BROADWAY, STE R, ALBANY, NY, United States, 12207

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
REGISTERED AGENTS INC. DOS Process Agent 418 BROADWAY, STE R, ALBANY, NY, United States, 12207

Agent

Name Role Address
REGISTERED AGENTS INC. Agent 418 BROADWAY, STE R, ALBANY, NY, 12207

Filings

Filing Number Date Filed Type Effective Date
220728002935 2022-07-28 CERTIFICATE OF INCORPORATION 2022-07-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347386807 0215800 2024-04-02 BOSNIAN ISLAMIC ASSOCIATION 306 COURT STREET, UTICA, NY, 13502
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2024-04-02
Emphasis N: FALL

Related Activity

Type Complaint
Activity Nr 2195084
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-08-23
Abatement Due Date 2024-09-27
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-10-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Bosnian Islamic Association, 306 Court Street, Utica, NY 13502 - On the tower roof, on or about 4/1/24: Employees were installing a roofing system onto the intermediate portion of a tower roof with a low pitch and a ground to eave height of approximately 60 feet, without having been trained on the use of fall protection equipment or with the hazards associated with fall hazards when working at heights. Abatement certification must be submitted for this item.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260501 B10
Issuance Date 2024-08-23
Current Penalty 32265.0
Initial Penalty 32265.0
Final Order 2024-10-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. a) Bosnian Islamic Association, 306 Court Street, Utica, NY 13502 - On the tower roof, on or about 4/1/24: Employees were installing a roofing system onto the intermediate portion of a tower roof with a low pitch and a ground to eave height of approximately 60 feet, without fall protection of any kind.

Date of last update: 21 Mar 2025