Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-24
|
Case Closed |
2023-11-06
|
Related Activity
Type |
Complaint |
Activity Nr |
2012250 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100101 B |
Issuance Date |
2023-08-28 |
Abatement Due Date |
2023-09-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-10-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Worksite, 16 Vatrano Road, Albany, New York, Holding Area: On or about March 24, 2023, for employees working within the holding area, seven compressed carbon dioxide cylinders were not secured while being stored. b) Worksite, 16 Vatrano Road, Albany, New York, Laboratory: On or about March 24, 2023, for employees working in the laboratory, nine compressed carbon dioxide cylinders were not secured while being stored. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2023-08-28 |
Abatement Due Date |
2023-09-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-10-11 |
Nr Instances |
3 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Worksite, 16 Vatrano Road, Albany, New York, break room microwave: On or about March 24, 2023, there was an outlet that did not have a cover, faceplate, or canopy. Employees are exposed to an electric shock hazard when plugging or unplugging the microwave. b) Worksite, 16 Vatrano Road, Albany, New York, break room refrigerator: On or about March 24, 2023, there was an outlet that did not have a cover, faceplate, or canopy. Employees are exposed to an electric shock hazard when plugging or unplugging the refrigerator. c) Worksite, 16 Vatrano Road, Albany, New York, break room wall: On or about March 24, 2023, there was an outlet that did not have a cover, faceplate, or canopy. Employees are exposed to an electric shock hazard when plugging or unplugging on outlet. |
|
|