Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-01-13
|
Case Closed |
2017-03-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1017833 |
Safety |
Yes |
|
Type |
Complaint |
Activity Nr |
932081 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2015-07-02 |
Current Penalty |
1500.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-09-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Employees worked near unguarded floor holes on the 3rd floor. Employees exposed to falls of approximately 10 feet. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 A03 |
Issuance Date |
2015-07-02 |
Abatement Due Date |
2015-07-22 |
Current Penalty |
1250.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-09-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(a)(3): Variations in riser height or tread depth were not uniform in the stairway system. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Stairway leading from the 1st level to the 3rd level was missing the riser/steps, employees were exposed to trip and fall hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 |
Issuance Date |
2015-07-02 |
Abatement Due Date |
2015-07-22 |
Current Penalty |
1250.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-09-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Stairway leading from the 1st level to the 3rd level was not equipped with a handrail or stairrail. |
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-10-30
|
Emphasis |
L: FALL, L: GUTREH
|
Case Closed |
2017-08-24
|
Related Activity
Type |
Complaint |
Activity Nr |
918808 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1005362 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1055552 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2015-04-28 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-05-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood whcih completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut. Location; 145 west 126th Street, New York, NY 2nd Floor On or About October 30, 2014 a). Employees were using a portable 10" table saw to rip materials to repair/restore old entry doors and were exposed to amputation hazards because the saw blade above the rip table was not protected by the manufacturer provided guard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2015-04-28 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-05-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous LOCATION: 145 126th Street, New York, NY 10035, second floor front. On or About October 30, 2014 a) Employees were utilizing flexible extension cords to energize portable DeWalt Brand slide saw and table saw. The saws were not protected by a continuous path to ground because the flexible cord was missing the ground pin. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2015-04-28 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-05-22 |
Nr Instances |
3 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such hole. Location: 145 West 126th Street, New York, NY Roof level, Second Floor, 1st Floor. On or About October 30, 2014. A). Employees were engaged in the removal and demolition of roofing materials at the above location and were exposed to falls over 6 feet to the floor below because employer did not ensure each employee was protected by personal fall arrest systems, covers, or guardrail systems erected around such hole. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2015-04-28 |
Abatement Due Date |
2015-05-08 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-05-22 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Location: 145 West 126th Street, New York, NY On or About October 30, 2014 a). Employees were engaged in a demolition project and were exposed to immanent danger conditions. Employees said they were not issued personal fall protection from the employer nor had they been trained to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19261052 C12 |
Issuance Date |
2015-04-28 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-05-22 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: Location 145 West 126th Street, New York, NY , first and second floor. a). Employees engaged in a GUT/REHAB project were not protected from falling to the floors below because the handrail systems around the existing stairwells had been demolished. Employees were utilizing these stairs to traverse throughout the project. |
|
|