OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346965320 0215800 2023-09-05 1233 ERIE BOULEVARD WEST, SYRACUSE, NY, 13204
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2023-09-05
Emphasis N: HEATNEP, N: FALL

Related Activity

Type Complaint
Activity Nr 2077140
Safety Yes
Type Inspection
Activity Nr 1696530
Safety Yes
Type Inspection
Activity Nr 1696534
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-02-21
Current Penalty 4610.0
Initial Penalty 4610.0
Final Order 2024-04-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 1233 Erie Boulevard West, Syracuse, NY 13204. On or about 9/5/23, on the roof. Workers were installing roofing materials onto a 3:12 pitch roof with a ground to eave height of up to 10 feet without fall protection of any kind.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-02-21
Abatement Due Date 2024-04-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-04-24
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a) 1233 Erie Boulevard West, Syracuse, NY 13204. On or about 9/5/23, on the roof. Workers were installing roofing materials onto a 3:12 pitch roof with a ground to eave height of up to 10 feet without having been trained to correctly use personal fall protection equipment. Abatement certification is required for this item.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-02-21
Current Penalty 0.0
Initial Penalty 4610.0
Final Order 2024-04-24
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 1233 Erie Boulevard West, Syracuse, NY 13204. On or about 9/5/23, on the roof. Workers were accessing a roof surface at 10 feet from ground with a portable ladder that did not extend at least 3 feet above that landing.