Search icon

SKYLINE DRYWALL LLC

Company Details

Name: SKYLINE DRYWALL LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 05 Apr 2023 (2 years ago)
Entity Number: 6791745
ZIP code: 12207
County: Albany
Place of Formation: New York
Address: 418 BROADWAY, STE N, ALBANY, NY, United States, 12207

DOS Process Agent

Name Role Address
NORTHWEST REGISTERED AGENT LLC DOS Process Agent 418 BROADWAY, STE N, ALBANY, NY, United States, 12207

Agent

Name Role Address
NORTHWEST REGISTERED AGENT LLC Agent 418 BROADWAY, STE N, ALBANY, NY, 12207

History

Start date End date Type Value
2023-04-06 2024-01-24 Address 418 BROADWAY, STE N, ALBANY, NY, 12207, USA (Type of address: Registered Agent)
2023-04-06 2024-01-24 Address 418 BROADWAY, STE N, ALBANY, NY, 12207, USA (Type of address: Service of Process)
2023-04-05 2023-04-06 Address 418 BROADWAY, STE N, ALBANY, NY, 12207, USA (Type of address: Registered Agent)
2023-04-05 2023-04-06 Address 109-15 DITMARS BLVD, FLOOR 1, EAST ELMHURST, NY, 11369, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240124001704 2024-01-23 CERTIFICATE OF PUBLICATION 2024-01-23
230406003274 2023-04-06 CERTIFICATE OF CHANGE BY ENTITY 2023-04-06
230405004248 2023-04-05 ARTICLES OF ORGANIZATION 2023-04-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346972011 0216000 2023-07-12 56 PROSPECT ST., YONKERS, NY, 10701
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2023-09-13
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2023-09-14
Current Penalty 5338.0
Initial Penalty 10938.0
Nr Instances 2
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 4th floor elevator shaft On or about: 7/12/23 a) Employees were installing wooden guardrails for fall protection The employees were not protected from falling 40', to the ground below. Location: level 1, over parking garage On or about: 7/12/23 b) Employees were installing wooden guardrails for fall protection The employees were not protected from falling 20', to the ground below. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2023-09-14
Current Penalty 3062.0
Initial Penalty 6250.0
Nr Instances 2
Nr Exposed 14
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: location: between 1st and 4th floors on or about: 7/12/23 a) Employees used two sets of stairs for access between the first and fourth floors. Neither of the two open sided stairs had midrails along the open sides. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.