Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-08-24
|
Emphasis |
N: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260416 A01 |
Issuance Date |
2024-02-12 |
Current Penalty |
2903.4 |
Initial Penalty |
4839.0 |
Final Order |
2024-05-29 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(a)(1): The employer did not prevent employee(s) from working in proximity to an electric power circuit that the employee could contact during the course of work and the employee(s) were not protected against electric shock by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means: a) 152 Wilson Drive Syracuse NY 13057: On or about 8/24/2023, the employer did not protect employee(s) from possible electrical shock when employees were using multiple tools, including but not limited to a metal shovels/scrapers in close proximity to incoming 240-volt electrical lines. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-02-12 |
Current Penalty |
4839.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-05-29 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 152 Wilson Drive, East Syracuse, NY 13057: On or about 8/24/2023, employer did not ensure employees engaged in residential construction activities on a 1-story house, with a roof pitch of approximately 5:12 and a fall distance of greater than 8 feet, were protected by guardrail systems, safety net systems, or personal fall arrest systems. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-02-12 |
Current Penalty |
0.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-05-29 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (0.9 m) above the upper landing surface being accessed: a) 152 Wilson Drive, Syracuse, NY 13057: On or about 8/24/2023 employees were using portable extension ladders for roof access/egress that were not extended 3-feet above the upper landing surface being accessed. |
|
|