Inspection Type |
Fat/Cat
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-10-05
|
Emphasis |
N: FALL
|
Case Closed |
2025-01-13
|
Related Activity
Type |
Accident |
Activity Nr |
2089620 |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-04-02 |
Current Penalty |
16131.0 |
Initial Penalty |
16131.0 |
Final Order |
2024-05-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): A). On or about 10/03/2023, at the site of 140-36 Negundo Ave. Flushing, NY An employee removing roof shingles from a 3 and 12 pitched roof was not protected from falling approximately 24 feet by any type of fall protection system. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260502 D15 |
Issuance Date |
2024-04-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-05-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds per employee attached: A). On or about 10/03/2023, at the site of 140-36 Negundo Ave. Flushing, NY Two employees were each using a separate personal fall arrest system while working from a 3 and 12 pitched roof. The roof brackets for each personal fall arrest system were fastened to the roof using only 3 of a possible 32 fasteners. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 II |
Issuance Date |
2024-04-02 |
Abatement Due Date |
2024-04-19 |
Current Penalty |
3457.0 |
Initial Penalty |
3457.0 |
Final Order |
2024-05-15 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems that were used: A). On or about 10/03/2023, at the site of 140-36 Negundo Ave. Flushing, NY Employees utilizing a personal fall arrest system were not trained in the appropriate method of installing an anchor point. Only 3 out of 32 fasteners were used to secure the roof anchor bracket to the roof. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A01 |
Issuance Date |
2024-04-02 |
Current Penalty |
3803.0 |
Initial Penalty |
3803.0 |
Final Order |
2024-05-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident: A). On or about 10/03/2023, at the site of 140-36 Negundo Ave. Flushing, NY The employer did not report to OSHA the death of an employee as a result of a work-related incident. An employee removing shingles from a 3 and 12 pitched roof, fell approximately 24 ft to the ground. |
|
|