OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344149737 0215800 2019-07-12 2900 MCLANE DRIVE, BALDWINSVILLE, NY, 13027
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-07-12
Emphasis P: AMPUTATE, N: AMPUTATE
Case Closed 2019-07-26

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2019-07-16
Current Penalty 2717.25
Initial Penalty 3623.0
Final Order 2019-07-18
Nr Instances 1
Nr Exposed 9
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Maintenance Shop, on or about 7/12/19: A Dayton 10" Bench Grinder had an opening between the work rest and grinding wheel that measured 3/8-inch at the left wheel.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2019-07-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-07-18
Nr Instances 1
Nr Exposed 9
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Maintenance Shop, on or about 7/12/19: A Dayton 10" Bench Grinder had an had an opening between the tongue guard and grinding wheel that measured 3/4 inch at the left wheel.
341046100 0215800 2015-11-09 2900 MCLANE DR, BALDWINSVILLE, NY, 13027
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2015-11-09
Emphasis L: FORKLIFT, N: AMPUTATE
Case Closed 2016-02-16

Related Activity

Type Complaint
Activity Nr 1035683
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100219 C02 I
Issuance Date 2015-12-10
Current Penalty 0.0
Initial Penalty 4000.0
Final Order 2016-01-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. a) Machine 246, Production floor, On or about 11/9/15: An spinning horizontal shaft was not properly guarded or enclosed.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100303 F01
Issuance Date 2015-12-10
Current Penalty 3000.0
Initial Penalty 4000.0
Final Order 2016-01-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). a) Panel Box HP10/ICP Control Panel box, On or about 11/9/15: An open breaker slot was found exposing the main bus bar terminal exposing personnel to shock hazard.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100303 F02
Issuance Date 2015-12-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-01-11
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. a) Panel Box R2B/S, On or about 11/9/15: Panel box circuit breakers were not labeled to show its purpose.
Citation ID 02001
Citaton Type Other
Standard Cited 19100037 A04
Issuance Date 2015-12-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-01-11
Nr Instances 2
Nr Exposed 220
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times. a) 2900 McLane Dr, Baldwinsville, NY 13027 warehouse/Production Floor, On or about 11/9/15: Emergency lights did not illuminate when tested.

Date of last update: 20 Mar 2025