343761482
|
0213100
|
2019-02-05
|
629 COLUMBIA ST. EXT., LATHAM, NY, 12110
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-02-05
|
Emphasis |
L: FALL
|
Case Closed |
2019-07-05
|
Related Activity
Type |
Referral |
Activity Nr |
1422546 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1377463 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260251 C16 |
Issuance Date |
2019-05-23 |
Abatement Due Date |
2019-06-05 |
Current Penalty |
6630.0 |
Initial Penalty |
6630.0 |
Final Order |
2019-06-20 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.251(c)(16): Wire rope slings did not have have permanently affixed, legible identification markings stating size, rated capacity for the type(s) of hitch(es) used and the angle upon which it is based, and the number of legs. a) 629 Columbia St. Ext: On or about 1/31/19 Employer provided multiple legged sling for usage in steel erection without identification markings that meet the OSHA standards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261419 E |
Issuance Date |
2019-05-23 |
Abatement Due Date |
2019-05-30 |
Current Penalty |
0.0 |
Initial Penalty |
9282.0 |
Final Order |
2019-06-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1419(e): Suitability. The signals used (hand, voice, audible, or new), and means of transmitting the signals to the operator (such as direct line of sight, video, radio, etc.), were not appropriate for the site conditions: a) 629 Columbia St. Ext: On or about 1/31/19, an employee was utilizing hand signals at a distance of approximately 220 feet (73 yds.) to direct the operator. This method was not suitable due to the distance and the angle of the sun at times affecting the operators ability to view the signals given. |
|
|
313761652
|
0213100
|
2010-11-24
|
29 CONSUMER SQUARE, PLATTSBURGH, NY, 12901
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-11-24
|
Emphasis |
S: COMMERCIAL CONSTR, S: ELECTRICAL, L: FALL, S: FALL FROM HEIGHT
|
Case Closed |
2011-07-25
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2011-04-06 |
Abatement Due Date |
2011-04-11 |
Current Penalty |
1890.0 |
Initial Penalty |
2700.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260454 C03 |
Issuance Date |
2011-04-06 |
Abatement Due Date |
2011-04-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260761 C03 I |
Issuance Date |
2011-04-06 |
Abatement Due Date |
2011-05-31 |
Current Penalty |
2610.0 |
Initial Penalty |
3780.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
|
|
310751706
|
0215800
|
2007-10-18
|
142 MECHANIC STREET, WATERTOWN, NY, 13601
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2007-10-18
|
Emphasis |
L: FALL
|
Case Closed |
2007-10-22
|
|