OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347274995 0216000 2024-02-12 12 HILLSIDE AVE, VALHALLA, NY, 10595
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-02-12
Emphasis N: FALL

Related Activity

Type Referral
Activity Nr 2130343
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2024-03-29
Current Penalty 3144.0
Initial Penalty 4839.0
Final Order 2024-04-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. On or about February 12th, 2024 Location: 12 Hillside Ave, Valhalla, NY 10595. a) Employees working on a peak roof (12:12 ; rise: run) at a height of about 20 ft from the ground were exposed to fall because they connected to the same roof anchor plate.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-03-29
Current Penalty 3144.0
Initial Penalty 4839.0
Final Order 2024-04-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about February 12th, 2024 Location: 12 Hillside Ave, Valhalla, NY 10595. a) Employees accessed a 12:12 (rise:run) peak roof through an extension ladder that did not extend 3 ft above the upper landing. Upper landing was about 20 ft from the ground level.

Date of last update: 19 Mar 2025

Sources: New York Secretary of State