Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-06-23
|
Emphasis |
L: FALL, L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2015-09-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2015-06-26 |
Abatement Due Date |
2015-07-09 |
Current Penalty |
840.0 |
Initial Penalty |
1200.0 |
Final Order |
2015-07-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On or about 6/23/2015, At the jobsite: A set of stairs located between the first and second floor which were being utilized as part of the construction activities was lacking hand rails. Abatement certification is required for this item. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 II |
Issuance Date |
2015-06-26 |
Abatement Due Date |
2015-07-09 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-07-16 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stair rail system along each unprotected side or edge: a) On or about 6/23/2015, At the jobsite: A set of temporary wooden stairs between the basement and the first floor were not provided with a stair rail system on an open side, and a lack of a mid rail on another open side. The stairs consisted of fifteen risers. b) On or about 6/23/2015, At the jobsite: A set of stairs located between the first and second floor which were being utilized as part of the construction activities was lacking a mid rail below the upper landing, this section of the stair consisted of four risers. Abatement certification is required for this item. |
|
|